PAGE 28 — TLG-12SPX — PARTS AND OPERATION MANUAL (STD) — REV. #4 (03/08/05)
TLG-12SPX FAMILIARIZATION
The Output Terminal panel is provided with the following:
One GFCI 120 Volt Receptacle, 20 Amp (single-phase)
Ground Terminal (for GFCI receptacle)
Main Circuit Breaker 50 amps
GFCI Circuit Breaker 20 amps
NEMA L530R Output Receptacle
NEMA L630R Output Receptacle
NEMA CS6369 Output Receptacle
Output Terminal Panel
The Output Control Panel (See Figure 6) is located on the
rear (Control Panel) end of the generator. The UNV lugs are
protected by a face plate cover that can be secured in the
close position by a 6mm bolt (See Figure 7).
120 Volt Receptacle
One GFCI Duplex Nema 5-20R (120V, 20 Amp) receptacle
is provided on the output terminal. This receptacle can be
used anytime the generator is in operation. The receptacle
is controlled by the circuit breaker located on the control
panel.
Pressing the reset button will reset the GCFI receptacle if it
is tripped. Pressing the "Test Button" (See Figure 2) in the
center of this receptacle will check the GFCI function. The
receptacle should be tested at least once a month.
Figure 9. GFCI Test
Button
Figure 8. Retaining Bolt
NEMA L5-30R Output Receptacle
The L5-30R receptacle supplies 30 amps at 120 volts. A 30
amp circuit breaker helps protect any load being used.
NEMA L6-30R Output Receptacle
The L6-30R is a receptacle that supplies 30 amps at 240
volts. The 30 amp circuit breaker helps protect any load
being used.
NEMA CS-6369 Output Receptacle
The CS-6369 is a receptacle that supplies 50 amps at 120/
240 volts. A 50 amp circuit breaker helps protect any load
being used. See Figure 12 for details.
Connecting Load
Loads are to be connected to the generator by the
receptacles supplied. Make sure to read the operation
manual before attempting to connect a load to the generator.
Maximum Output
The entire load connected to the UNV Lugs and both slots in
the duplex receptacle must not exceed 13 kW in standby or 12
kW in prime output.
Output Terminal Panel Available Voltages
The TLG12SPX is a single phase generator only. It is able
to supply both 120 volt and 240 volt.
Maximum Amps
The generator unit provides 50 amps of power. Do not
exceed the maximum amps!
When using plural single phase
voltages, make sure to balance
the load on each of the single
phase legs.
NOTE
TLG-12SPX — OUTPUT TERMINAL PANEL