ERROR MESSAGES
Rinnai water heaters have the ability to check their own operation continuously. If a fault occurs, an error code will flash on the Digital Display if you have temperature controllers installed. This assists with diagnosing the fault, and may enable you to overcome a problem without a service call. Please quote the code displayed when enquiring about service. Some of these remedies can not be checked by the user because they require the front to be taken off of the unit. They are included so that you can give the information to the gas engineer.
Code | Fault | Remedy |
Displayed |
|
|
|
|
|
- | Noticeable reduction in water | Inlet water filter needs to be cleaned. |
| flow |
|
|
|
|
10 | Not enough combustion air | Check for physical blockages around |
|
| air intake or exhaust. Check combus- |
|
| tion fan. |
11 | No Ignition / Gas supply | Check gas valves, gas supply and |
|
| ignition unit. |
|
|
|
12 | Flame failure / Earth Leakage | Check gas valves and gas supply. |
|
| Check flame rod. |
|
| Check earth wire lead. |
|
| Check remote control. |
|
|
|
14 | High flame safety device | Check overheat circuit |
|
|
|
16 | Over temperature warning | Modulating control valve problem or |
|
| water flow control valve problem |
32 | Outgoing water temperature | Check Hot Water Thermistor and wire |
| sensor faulty |
|
|
|
|
34 | Combustion Air temperature | Check Air Intake Thermistor and wire |
sensor faulty |
| |
|
| |
|
|
|
52 | Gas modulating valve faulty | Check gas modulating valve and pcb. |
|
|
|
61 | Combustion fan failure | Check Combustion Fan |
|
|
|
71 | Check solenoids and pcb. | |
| noid circuit failure |
|
72 | Flame rod circuit error | Check flame rod and pcb. |
|
|
|
*In all cases, you may be able to clear the Error code by turning the hot water tap OFF, then ON again. If this does not clear the error, try pushing the On/Off button OFF then ON again. If the Error Code still remains contact Rinnai or your nearest service agent for advice.
**Faults caused by insufficient gas/water supply or gas/water quality and installation errors are not covered by the manufacturer’s warranty.
Regular maintenance should be performed by a competent person in accordance with the local regulations at least once annually.