Rinnai REU - 16 FUA - E user manual Specification

Models: REU - 16 FUA - E

1 51
Download 51 pages 60.31 Kb
Page 50
Image 50
SPECIFICATION

SPECIFICATION

Model………………………………………………..…....…………......................Infinity 16i

Installation…………………………………………...………...……... Internal location only

Fuel…………………………………………………..….…………..…...Natural Gas or LPG *

Control………………………………………………….……………...…….….…..Modulating

Output (nominal)………………..………………………...…..……….………4 kW to 30 kW

Exhaust type…………………………………………...…………….....Forced Draught Flue

Ignition………………………………………………...…………….………………..Electronic

Burner……………………………………………………...…………………....Stainless steel

Weight…………………………………………………...……….……………..…..………15kg

Water flow rate ………………………………………..……………….…...2.4** to 20 L/min

Minimum operating water pressure…………………..……….………..…..……….1.0 Bar

Connections

Gas…………………………………………………………...….………………….…….1/2BSP

Water Inlet………………………………………….………...……………….…….……1/2BSP

Water outlet…………………………………….………...………………………….…..1/2BSP

Electrical Supply…………………………….…………..…………….….230V AC 50Hz 1ph

* Separate models available for Natural gas or LPG fuel.

** Minimum flow rate based on temperature setpoint and inlet conditions.

Rinnai are continually updating and improving products and reserve the right to alter model specifications without prior notice.

50

Page 50
Image 50
Rinnai REU - 16 FUA - E user manual Specification