TECHNICAL DETAILS
Infinity Model | Infinity 16i | Units |
|
|
|
|
|
|
|
Installation | Internal |
|
|
|
|
|
|
|
|
G20 Nat Gas Press Low | 1.8 | mbar |
|
|
|
|
|
|
|
G20 Nat Gas Press High | 9.0 | mbar |
|
|
|
|
|
|
|
G25 Nat Gas Press Low | 1.8 | mbar |
|
|
|
|
|
|
|
G25 Nat Gas Press High | 9.0 | mbar |
|
|
|
|
|
|
|
G30 LPG (Butane) Press Low | 2.2 | mbar |
|
|
|
|
|
|
|
G30 LPG (Butane) Press High | 11.4 | mbar |
|
|
|
|
|
|
|
G31 LPG (Propane) Press Low | 2.2 | mbar |
|
|
|
|
|
|
|
G31 LPG Propane) Press High | 14.2 | mbar |
|
|
|
|
|
|
|
Height | 675 | mm |
|
|
|
|
|
|
|
Width | 370 | mm |
|
|
|
|
|
|
|
Depth | 130 | mm |
|
|
|
|
|
|
|
Weight | 15 | kg |
|
|
|
|
|
|
|
Flue System | Concentric Forced Draught |
|
| |
|
|
|
|
|
Temp. Range Controllers | 35 - 60 | deg C |
|
|
|
|
|
|
|
Max Temp. via dip switch | 75 | deg C |
|
|
|
|
|
|
|
Ignition | Direct Electronic Ignition |
|
| |
|
|
|
|
|
Gas Consumption Low (Gross) |
|
|
|
|
|
|
|
|
|
G20 Nat Gas | 4.7 | kW | 0.4 | m3/hr |
G25 Nat Gas | 4.0 | kW | 0.4 | m3/hr |
G30 LPG (Butane) | 4.9 | kW | .35 | kg/hr |
|
|
|
|
|
G31 LPG (Propane) | 4.9 | kW | .35 | kg/hr |
|
|
|
|
|
Gas Consumption High (Gross) |
|
|
|
|
|
|
|
|
|
G20 Nat Gas | 34.9 | kW | 3.26 | m3/hr |
G25 Nat Gas | 29.6 | kW | 3.26 | m3/hr |
G30 LPG (Butane) | 36.8 | kW | 2.6 | kg/hr |
|
|
|
|
|
G31 LPG (Propane) | 36.5 | kW | 2.6 | kg/hr |
|
|
|
|
|
Max Flow raised 25C | 15.2 | L/min |
|
|
|
|
|
|
|
Min Operation Flow | 2.4* | L/min |
|
|
|
|
|
|
|
Water Pressure Nom. | 1.1 - 7.0 | bar |
|
|
|
|
|
|
|
Power Supply | 230 V / 50 Hz |
|
|
|
|
|
|
|
|
Electric Consumption | 68 | Watts |
|
|
|
|
|
|
|
* Minimum operation flow based on temperature setpoint and inlet conditions.
42