Rinnai REU - 16 FUA - E Installation Instructions - Schematics, Single Infinity Direct Flow

Models: REU - 16 FUA - E

1 51
Download 51 pages 60.31 Kb
Page 28
Image 28
INSTALLATION INSTRUCTIONS - SCHEMATICS

INSTALLATION INSTRUCTIONS - SCHEMATICS

Single Infinity Direct Flow

Direct feed to the hot water outlets.

Mains is fed directly into the unit.

Standard domestic or small commercial set up.

Used with controllers to alter the temperature at the point of use (only using hot tap) or temperature set on the dip switches for the maximum needed at any outlet, and mixed down by TMVs or manual tempering valves.

This information is intended as a guide only, it does not imply compliance with water or gas installation regulations. Components will vary depending on the actual installation. Check local regulations before installation.

Draining Point

Manifolded Infinity x 2 With Pumped Secondary.

Hot Water

Cold Water

Single Infinity Direct Flow Pump

Gas

Circulation system used in commercial situations where the heaters are not close to the outlets. Ensures hot water is available at the outlets quickly, without a lot of wastage.

Mains is fed to the unit via a header pipe that branches off to each heater. The secondary return is Tee’ed in to the heater’s supply. A complete unvented kit is required as it is a closed system.

PAM valves included to decrease flow rate needed from pump.

Temperature is set on the dip switches for the required circulation. 60°C for most applications.

Return Water

This information is intended as a guide only, it does not imply compliance with water or gas installation regulations. Components will vary depending on the actual installation. Check local regulations before installation.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pressure

Non-

 

 

 

 

 

 

Flow

Draining Valve

Reducing Strainer

Return

Safety

Expansion

Modulation

Point

Valve

Valve

Valve

Vessel

Valve

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

28

Page 28
Image 28
Rinnai REU - 16 FUA - E Installation Instructions - Schematics, Single Infinity Direct Flow, Draining Point, Pump Gas