Rinnai REU - 16 FUA - E Dip Switch Setting, Dip Switch Positions Explained, Gas Type, Nat Gas

Models: REU - 16 FUA - E

1 51
Download 51 pages 60.31 Kb
Page 40
Image 40
DIP SWITCH SETTING

DIP SWITCH SETTING

Dip Switch Positions Explained

OFF ON SW

1- Gas Type

2- Gas Type

3- Computer Programming

4- Computer Programming

5- Computer Programming

6- Max. Temperature

7- Combustion

8- Combustion

Dip Switches Explained

GAS TYPE

 

 

 

 

 

LPG

 

NAT GAS

 

 

OFF ON SW

 

OFF ON

SW

 

 

 

1

off

 

 

1

on

 

 

2

off

 

 

2

off

COMPUTER PROGRAMMING

OFF ON SW

1Computer programming

2Switches (3-5) must be left

3in the factory set position

4for the Infinity 16i.

5

6

7

8

MAXIMUM TEMPERATURE

OFF ON

6 Maximum Temperature = 600C

6 Maximum Temperature = 750C

LEGEND:

Black Section indicates position of dip switch.

OFF ON

 

OFF ON

 

 

 

 

 

OFF ON

COMBUSTION

NORMAL

OFF ON SW

7 off

8 off

FORCED LOW

OFF ON SW

Dip Switch Positions Explained 7 on 8 off

FORCED HIGH

OFF ON SW 7 on 8 on

40

Page 40
Image 40
Rinnai REU - 16 FUA - E Dip Switch Setting, Dip Switch Positions Explained, Dip Switches Explained, Gas Type, Nat Gas