CAUTION:

This welder/AC generator is a source of providing LETHAL high voltages. Never permit unqualified personnel-especially children to operate the welder/AC generator.

This welder/AC generator is equipped with a ground terminal for your protection. Always complete the grounding path from the welder/AC generator to an external grounding source.

NEVER operate this welder/AC generator, or handle any electrical equipment while standing in water, while bare foot, while hands are wet, or in the rain. Dangerous electrical shock could occur causing severe bodily harm or even death.

This welder/AC generator requires an adequate free flow of cooling air. Never operate the welder/AC generator in any enclosed or narrow area where free flow of the air is restricted. If the air flow is restricted it will cause serious damage to the welder/AC generator and may cause injury to people.

Arc rays can cause blindness. Always wear protective shield when welding.

CAUTION:

NEVER touch output terminals or electrode during operation.This is extremely dangerous. Always stop the machine when contact with the output terminals and welding electrode.

CAUTION:

Never connect the welder/AC generator to house wiring. This is illegal and very dangerous. Electrical shock could occur causing damage to the welder/AC generator and bodily harm even death.

RULES FOR SAFE OPERATION

CAUTION:

Never use damaged or worn cables when connecting power tools or equipment to the welder/AC generator. Make sure power connecting cables are securely connected to the generator’s output terminals. Insufficient tightening of the terminal connections may cause damage to the welder/AC generator and electrical shock.

CAUTION:

DO NOT touch or open coolant drain plug, radiator cap, or engine oil drain plug while the welder/AC generator is running. Always allow sufficient time for the engine and generator to cool before performing maintenance.

Emergencies

Always know the location of the nearest fire extinguisher and first aid kit. Know the location of the nearest telephone. Also know the phone numbers of the nearest ambulance, doctor and fire department. This information will be invaluable in the case of an emergency.

Maintenance Safety

NEVER lubricate components or attempt service on a running machine.

Always allow the machine a proper amount of time to cool before servicing.

Keep the machinery in proper running condition.

Fix damage to the machine immediately and always replace broken parts.

Dispose of hazardous waste properly. Examples of potentially hazardous waste are used motor oil, fuel, coolant and fuel filters.

DO NOT use plastic containers to dispose of hazardous waste.

DO NOT pour waste, oil, coolant or fuel directly onto the ground, down a drain or into any water source.

TLW-300SS DC WELDER/ AC GENERATOR— OPERATION AND PARTS MANUAL— REV. #2 (04/07/10) — PAGE 7

Page 7
Image 7
Multiquip TLW-300SS operation manual Rules for Safe Operation

TLW-300SS specifications

The Multiquip TLW-300SS is a powerful and highly efficient water heater designed for a variety of applications in both construction and industrial settings. Known for its robust engineering and advanced technology, the TLW-300SS provides reliable hot water on demand, ensuring optimal performance even in the most challenging environments.

One of the main features of the TLW-300SS is its impressive heating capacity. With a substantial output of 300,000 BTUs, this water heater can quickly heat large volumes of water, making it ideal for tasks such as concrete curing, equipment washing, and site sanitation. The unit is equipped with a direct-fired stainless steel heat exchanger that ensures efficient heat transfer while minimizing energy consumption.

The TLW-300SS boasts dual-fuel capability, allowing users to operate the unit on either propane or natural gas. This versatility provides flexibility in fuel choices, enhancing usability in various locations and conditions. Furthermore, this water heater is designed with user-friendly controls, featuring a digital thermostat that allows precise temperature settings. This feature ensures consistent water temperatures, which is crucial for applications requiring specific heat levels.

Safety is a top priority with the TLW-300SS. The unit is equipped with various safety features, including an automatic flame failure shutdown system that prevents potential hazards by ceasing operation if the flame is extinguished unexpectedly. Additionally, it has a pressure relief valve to mitigate risks associated with excessive pressure buildup within the system.

Durability and maintenance are also significant considerations in the design of the TLW-300SS. Constructed from high-quality stainless steel, this unit resists corrosion and wear, making it suitable for both indoor and outdoor use. Easy access to key components simplifies maintenance and servicing, helping ensure that the unit operates at peak efficiency over its lifespan.

In terms of transportability, the TLW-300SS is built with a robust frame and towable design, allowing for easy mobility across job sites. Its compact size does not compromise its performance, making it able to fit into tight spaces while still delivering powerful heating capabilities.

In conclusion, the Multiquip TLW-300SS stands out in the market as a versatile, efficient, and safe water heating solution. Its combination of high heat output, dual-fuel operation, advanced safety features, and durable construction makes it a reliable choice for professionals in need of dependable hot water solutions in various work environments.