TLW-300SSPRE-SETUP

CAUTION :

When adding coolant or antifreeze to the radiator, do not remove the radiator cap until the unit has completely cooled.

Day-to-day addition of coolant or antifreeze is done from the reserve tank. See Table 9 for engine, radiator and reserve tank coolant capacities. Make sure the coolant level in the reserve tank is always between the "H" and the "L" markings.

Table 9. Coolant Capacity

Engine and Radiator

0.55 Gal.

 

 

Reserve Tank

0.27 Gal.

 

 

Cleaning the Radiator

The radiator may overheat if the fins become overloaded with dust or debris. Periodically clean the radiator fins with compressed air.

Fan Belt Tension

A slack fan belt may contribute to overheating, or to insufficient charging of the battery. Inspect and adjust it in accordance with the Kubota Engine Operator's Manual.

The fan belt tension is proper if the fan belt (Figure 10) bends 7 to 9 mm (0.28- to 0.35 in.) when depressed with the thumb as shown in Figure 5 below.

Operation in Freezing Weather

When operating in freezing weather, be certain that the proper amount of antifreeze has been added. See Table 10 for antifreeze operating temperatures.

Table 10. Anti-Freeze Operating Temperatures

Vol %

Freezing Point

Boiling Point

 

 

 

 

Anti-Freeze

°C

°F

°C

°F

 

 

 

 

 

 

40

-24

-12

106

222

 

 

 

 

 

50

-37

-34

108

226

 

 

 

 

 

NOTE

When the antifreeze is mixed with water, the antifreeze mixing ratio must be less than 50%.

Figure 10. Fan Belt Tension

CAUTION :

Never place hands near the belts or fan while the welder/AC generator is running.

Air Cleaner

Periodic cleaning/replacement is necessary. Inspect it in accordance with the Kubota Engine Operator's Manual.

Battery

This unit is of negative ground. DO NOT connect in reverse. Always maintain battery fluid level between the specified marks. Battery life will be shortened, if the fluid level is not properly maintained. Add only distilled water when replenishment is necessary.

The battery is sufficiently charged if the specific gravity of the battery fluid is 1.28 (at 68° F). If the specific gravity should fall to 1.245 or lower, it indicates that the battery is dead and needs to be recharged or replaced.

Check to see whether the battery cables are loose. Poor contact may result in poor starting or malfunctions, always keep the terminals firmly tightened. Coating the terminals with a thin film of grease will help to inhibit corrosion.

PAGE 26 — TLW-300SS WELDER/AC GENERATOR — OPERATION AND PARTS MANUAL — REV. #2 (04/07/10)

Page 26
Image 26
Multiquip TLW-300SS Cleaning the Radiator, Fan Belt Tension, Operation in Freezing Weather, Air Cleaner, Battery

TLW-300SS specifications

The Multiquip TLW-300SS is a powerful and highly efficient water heater designed for a variety of applications in both construction and industrial settings. Known for its robust engineering and advanced technology, the TLW-300SS provides reliable hot water on demand, ensuring optimal performance even in the most challenging environments.

One of the main features of the TLW-300SS is its impressive heating capacity. With a substantial output of 300,000 BTUs, this water heater can quickly heat large volumes of water, making it ideal for tasks such as concrete curing, equipment washing, and site sanitation. The unit is equipped with a direct-fired stainless steel heat exchanger that ensures efficient heat transfer while minimizing energy consumption.

The TLW-300SS boasts dual-fuel capability, allowing users to operate the unit on either propane or natural gas. This versatility provides flexibility in fuel choices, enhancing usability in various locations and conditions. Furthermore, this water heater is designed with user-friendly controls, featuring a digital thermostat that allows precise temperature settings. This feature ensures consistent water temperatures, which is crucial for applications requiring specific heat levels.

Safety is a top priority with the TLW-300SS. The unit is equipped with various safety features, including an automatic flame failure shutdown system that prevents potential hazards by ceasing operation if the flame is extinguished unexpectedly. Additionally, it has a pressure relief valve to mitigate risks associated with excessive pressure buildup within the system.

Durability and maintenance are also significant considerations in the design of the TLW-300SS. Constructed from high-quality stainless steel, this unit resists corrosion and wear, making it suitable for both indoor and outdoor use. Easy access to key components simplifies maintenance and servicing, helping ensure that the unit operates at peak efficiency over its lifespan.

In terms of transportability, the TLW-300SS is built with a robust frame and towable design, allowing for easy mobility across job sites. Its compact size does not compromise its performance, making it able to fit into tight spaces while still delivering powerful heating capabilities.

In conclusion, the Multiquip TLW-300SS stands out in the market as a versatile, efficient, and safe water heating solution. Its combination of high heat output, dual-fuel operation, advanced safety features, and durable construction makes it a reliable choice for professionals in need of dependable hot water solutions in various work environments.