TLW-300SS — ENGINE OPERATING INSTRUCTIONS

CAUTION:

The engine's exhaust contains harmful emissions. ALWAYS ventilate the exhaust when operating inside tunnels, excavations or buildings. Direct exhaust away from nearby personnel.

5.During winter or when the surrounding air temperature is cold, in situations where a load start is required, turn the key to the ‘HEAT’ position for a longer time.

6.If the engine does not start within 10 seconds after the key is turned to the ‘START’ position, wait for about 30 seconds and repeat the procedure as described in step 4.

CAUTION:

Check the fuel level on the fuel gauge.When fuel is low, fill the fuel tank with clean fresh DIESEL FUEL.

If fuel spillage occurs, wipe up the

Starting

spilled gasoline completely.

 

1. Turn the fuel cock lever to the “ON” position (Figure 13).

Figure 13. Fuel cock set to ‘ON’ position

2.Close door. Operation with the doors open may cause insufficient cooling to the unit, and damage may result.

3.Insert the key into the starter switch and turn it to the ‘ON’ position. Check to see the oil pressure and charge lights on the "Warning Lamp Unit " are lit. If either are not lit, check the system and wiring (refer to the Kubota Engine Operator's Manual).

4.Turn the key to the ‘PREHEAT’ position (Figure 14).When the preheat light glows, turn the key to the ‘START’position to start the engine. As soon as the engine starts, release the key. The key will automatically return to the ‘RUN’ position.

Figure 14. Key switch to ‘PREHEAT’ position

CAUTION:

NEVER turn the key to the ‘START’ position while the engine is running.

7.When the engine starts, the oil pressure light and charge light should go out. If these lights stay on, stop the engine immediately and check the system and wiring (refer to the Kubota Engine Operator's Manual).

8.Let the engine idle for five minutes with the automatic idle control switch in the ‘ON’ position.

9.Check the engine for abnormal vibrations, noises and oil leakage.

10.Check the generator's output voltage by referring to the AC voltmeter on the control panel. If the meter indicates 120 volts, then 120 VAC can be obtained from the 120 V and 240V receptacles at the same time.

CAUTION:

NEVER turn the key to the‘START’position while the engine is running.

Shutdown

1.Remove the load from the welder/AC generator, then place both the main and GFCI circuit breakers to the ‘OFF’ position.

2.Listen for the engine speed to drop. Run at low speed for 3-5 minutes.

3.Stop the engine by turning the key to ‘STOP’ position and remove the key. Turn the fuel cock lever to the ‘OFF’ position.

TLW-300SS DC WELDER/ AC GENERATOR— OPERATION AND PARTS MANUAL— REV. #2 (04/07/10) — PAGE 31

Page 31
Image 31
Multiquip TLW-300SS operation manual Starting, Shutdown

TLW-300SS specifications

The Multiquip TLW-300SS is a powerful and highly efficient water heater designed for a variety of applications in both construction and industrial settings. Known for its robust engineering and advanced technology, the TLW-300SS provides reliable hot water on demand, ensuring optimal performance even in the most challenging environments.

One of the main features of the TLW-300SS is its impressive heating capacity. With a substantial output of 300,000 BTUs, this water heater can quickly heat large volumes of water, making it ideal for tasks such as concrete curing, equipment washing, and site sanitation. The unit is equipped with a direct-fired stainless steel heat exchanger that ensures efficient heat transfer while minimizing energy consumption.

The TLW-300SS boasts dual-fuel capability, allowing users to operate the unit on either propane or natural gas. This versatility provides flexibility in fuel choices, enhancing usability in various locations and conditions. Furthermore, this water heater is designed with user-friendly controls, featuring a digital thermostat that allows precise temperature settings. This feature ensures consistent water temperatures, which is crucial for applications requiring specific heat levels.

Safety is a top priority with the TLW-300SS. The unit is equipped with various safety features, including an automatic flame failure shutdown system that prevents potential hazards by ceasing operation if the flame is extinguished unexpectedly. Additionally, it has a pressure relief valve to mitigate risks associated with excessive pressure buildup within the system.

Durability and maintenance are also significant considerations in the design of the TLW-300SS. Constructed from high-quality stainless steel, this unit resists corrosion and wear, making it suitable for both indoor and outdoor use. Easy access to key components simplifies maintenance and servicing, helping ensure that the unit operates at peak efficiency over its lifespan.

In terms of transportability, the TLW-300SS is built with a robust frame and towable design, allowing for easy mobility across job sites. Its compact size does not compromise its performance, making it able to fit into tight spaces while still delivering powerful heating capabilities.

In conclusion, the Multiquip TLW-300SS stands out in the market as a versatile, efficient, and safe water heating solution. Its combination of high heat output, dual-fuel operation, advanced safety features, and durable construction makes it a reliable choice for professionals in need of dependable hot water solutions in various work environments.