INSPECTION

HYDRAULIC OIL

Check hydraulic oil sight gauge (Figure 12) to ensure that hydraulic oil is at the midway level.

Figure 12. Hydraulic Oil Sight Gauge

HYDRAULIC HOSES

Check hydraulic hoses to make sure they are not worn, frayed or defective.

GREASE FITTINGS (BEARINGS)

Check the zerk grease fittings (Figure 13) on the bearing housings and dump support brackets at each end of the mixing drum. These grease fittings lubricate the dumping mechanism. If the dumping handle is stiff or hard to move lubricate these fittings.

Figure 14. Grease Fittings (Dump Cylinder)

BLADE CHECK

Check for worn or paddle blades. Make sure that all blades are adjusted properly. See blade adjustment procedure in this manual. Replace all defective or damaged blades immediately.

DUMP HANDLE (MANUAL DUMP MACHINES ONLY)

Before operating a manual dump mixer, ensure that the dump handle has been placed in the operating position. See Figure 15.

1.Remove and retain nuts (2) and bolts (2) that secure dump handle to the drum in towing position.

2.Place dump handle in operating position and re-install nuts and bolts to secure dump handle to drum.

Figure 13. Grease Fittings (Bearings)

GREASE FITTING (DUMP CYLINDER)

1. If your unit has hydraulic dump capability, check the zerk grease fitting at the top of the dump cylinder (Figure 14). This grease fitting lubricates the hydraulic dumping mechanism.

Figure 15. Dump Handle

WM120PH/SH HYDRAULIC MIXER • OPERATION AND PARTS MANUAL — REV. #7 (09/15/11) — PAGE 23

Page 23
Image 23
Multiquip WM120PH Hydraulic OIL, Hydraulic Hoses, Grease Fittings Bearings, Blade Check, Grease Fitting Dump Cylinder