Multitec

8Trouble-shooting

Pump delivers insufficient flow rate

Motor is overloaded

Pump is running, but does not deliver

Excessive bearing temperature

Leakage at the pump

Excessive leakage at the shaft seal

Vibrations during pump operation

Excessive rise of temperature inside the pump

Cause

Remedy 1)

*

 

*

 

 

 

 

*

Pump delivers against an excessively high discharge pressure.

Re-adjust to duty point.

 

 

 

 

 

 

Check plant for impurities.

 

 

 

 

 

 

 

 

 

Fit one or several larger impellers.

 

 

 

 

 

 

 

 

 

Increase the speed (turbine, I.C. engine).

 

 

 

 

 

 

 

 

 

 

*

 

*

 

 

 

*

*

Pump or piping are not completely vented or primed.

Vent and/or prime.

 

 

 

 

*

 

*

 

 

 

 

 

Supply line or impeller clogged.

Remove deposits in the pump and/or piping.

 

 

 

 

 

 

 

 

*

 

*

 

 

 

 

 

Formation of air pockets in the piping.

Alter piping layout.

 

 

 

 

 

 

 

Fit a vent valve.

 

 

 

 

 

 

 

 

 

 

*

 

*

 

 

*

*

*

Suction head is too high / NPSHavailable (positive suction head) is too low.

Check/alter liquid level.

 

 

 

 

Fully open shut-off valve in the suction line.

 

 

 

 

 

 

 

 

 

Change suction line, if the friction losses in the suction line are too high.

 

 

 

 

 

 

 

 

 

Check suction strainer/foot valve and suction line for clogging.

 

 

 

 

 

 

 

 

 

 

*

 

*

 

 

 

 

 

Air intake at the shaft seal.

Clean barrier liquid duct, supply external barrier liquid, if necessary2) 3) , or

 

 

 

 

 

 

 

increase its pressure.

 

 

 

 

 

 

 

 

 

Fit new shaft seal.

 

 

 

 

 

 

 

 

 

 

*

 

*

 

 

*

 

 

Wrong direction of rotation.

Interchange two of the phases of the power supply cable.

 

 

 

 

 

Speed is too low. 2)

Increase speed.

*

 

 

 

 

 

 

 

Wear of internal pump parts.

Replace worn components by new ones.

*

*

 

*

 

 

*

 

 

 

 

 

Pump back pressure is lower than specified in the purchase order.

Adjust duty point accurately.

 

*

 

 

 

 

*

 

 

 

 

 

 

 

Density or viscosity of the fluid pumped is higher than stated in the pur-

2)

*

*

 

 

 

 

 

 

 

 

 

 

 

 

chase order.

 

 

*

 

 

 

*

 

*

Gland cover too tight or askew.

Correct. Increase leakage slightly.

 

 

 

 

 

Speed is too high.

Reduce speed. 2)

 

*

 

 

*

 

 

 

Tie bolts / gaskets

Tighten the bolts.

 

 

 

 

 

 

 

 

Fit new gaskets.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*

 

 

Worn shaft seal.

Fit new shaft seal.

 

 

 

 

 

 

 

 

Check barrier liquid pressure 2) 3)

 

 

 

 

 

*

 

 

Score marks or roughness on shaft protecting sleeve / shaft sleeve.

Replace shaft protecting sleeve / shaft sleeve.

 

 

 

 

 

 

 

 

Fit new shaft seal.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*

 

 

Vibrations during pump operation

Improve suction conditions.

 

 

 

 

 

 

 

 

Re-align the pump.

 

 

 

 

 

 

 

 

 

Re-balance the impeller.

 

 

 

 

 

 

 

 

 

Increase pressure at the pump suction nozzle.

 

 

 

 

 

 

 

 

 

 

 

 

 

*

 

*

*

 

The unit is misaligned.

Re-align.

 

 

 

 

 

Pump is warped or sympathetic vibrations in the piping.

Check pipeline connections and secure fixing of pump; if required, reduce

 

 

 

*

 

*

*

 

 

the distances between the pipe clamps.

 

 

 

 

 

 

 

 

 

Fix the pipelines using anti-vibration material.

 

 

 

 

 

 

 

 

 

 

 

 

 

*

 

 

 

 

Outer bearing races of fixed bearing are loose.

Clamp outer bearing races axially.

 

 

 

 

 

 

 

 

 

 

 

 

*

 

 

 

 

Increased axial thrust. 2)

Check rotor clearances, axial adjustment and clearance on throttling bush

 

 

 

 

 

 

 

 

/ balance drum.

 

 

 

 

 

 

 

 

 

 

 

 

 

*

 

 

*

 

Insufficient or excessive quantity of lubricant or unsuitable lubricant.

Top up, reduce or change lubricant.

 

 

 

 

 

 

Non-compliance with specified coupling distance.

Correct distance according to the general arrangement drawing.

 

 

 

*

 

 

 

 

*

*

 

 

 

 

 

Motor is running on two phases only.

Replace the defective fuse.

 

 

 

 

 

 

 

Check the electric cable connections.

 

 

 

 

 

 

 

 

 

 

 

 

 

*

 

*

*

 

Rotor is out of balance.

Clean the impellers.

 

 

 

 

 

 

Re-balance the impeller.

 

 

 

 

 

 

 

 

 

 

 

 

 

*

 

*

*

 

Defective bearing(s).

Fit new bearing(s).

 

 

 

 

 

 

 

 

 

 

*

 

 

*

*

Insufficient rate of flow.

Increase the minimum rate of flow.

 

 

 

*

Incorrect inflow of circulation liquid.

Increase the free cross-section.

 

 

 

 

 

 

 

*

*

*

 

 

*

 

In case of parallel operation, check valve defective or missing.

Check.

 

 

 

 

 

 

*

 

Incorrect installation of gland packing,

Check.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

unsuitable packing material

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*

 

*

 

*

Inadequate cooling of shaft seal chamber

Check the free cross-section of the cooling liquid feed line.

*

 

 

 

 

Change in the free cross-section of the return line of the balancing liquid

Check the balancing line.

 

 

*

 

*

 

 

Wear in balancing device

Check throttling bush / balance drum clearances.

1)Pump pressure must be released before attempting to remedy faults on parts which are subjected to pressure.

2)Contact KSB

3)Pump version with barrier liquid supply on request only

26

Page 26
Image 26
Multitech 1777.8/7-10 G3 operating instructions Multitec Trouble-shooting

1777.8/7-10 G3 specifications

The Multitech 1777.8/7-10 G3 is a prominent device designed for the evolving landscape of communication technology. This multi-functional solution becomes essential for businesses and organizations that demand flexibility and reliability in their network infrastructure.

One of the main features of the Multitech 1777.8/7-10 G3 is its support for multiple communication interfaces. This device can handle several protocols, enabling seamless connectivity regardless of the environment. The built-in support for both voice and data services makes it an attractive solution for various applications, from remote offices to industrial settings.

In terms of technologies, the device stands out with its advanced modular design. Users can easily customize the device with different interface cards based on their specific communication needs. This adaptability ensures that organizations can scale their operations without needing to invest in entirely new hardware as their requirements change.

The Multitech 1777.8/7-10 G3 also emphasizes high security and reliability. It implements multiple security features, including encryption and authentication processes, safeguarding sensitive data transmission. These features are particularly important for organizations that must comply with strict regulatory requirements.

Another characteristic of the Multitech 1777.8/7-10 G3 is its robust performance under various operating conditions. The device is engineered for durability and can withstand significant environmental stresses, making it ideal for deployment in less than optimal locations.

Moreover, the integration of VoIP capabilities allows users to benefit from cost-effective voice communication solutions. This convergence of voice and data services streamlines operations and reduces overall costs while maintaining high-quality service.

The user-friendly interface of the Multitech 1777.8/7-10 G3 ensures that system administrators can easily configure and manage the device. comprehensive monitoring and reporting functions enable businesses to keep track of their network performance, ensuring that they can address any potential issues proactively.

To summarize, the Multitech 1777.8/7-10 G3 is a testament to modern communication technologies, combining flexibility, security, and ease of use while equipping businesses with the tools necessary for efficient operations in a rapidly changing digital landscape.