CONNECTING THE UNIT
For 405FX & 405FXE units, remove the dust cap from the fiber optic connectors and connect the fiber optic cables. The TX port on the 405FX should be connected to the RX port of the far end station. The RX port on the 405FX should be connected to the TX port of the far end station.
For 10/100
Warning: Creating a port to port connection on the same switch (i.e. loop) is an illegal operation and will create a broadcast storm which will crash the network!
TROUBLESHOOTING
1.Make sure the (Power LED) is ON.
2.Make sure the ! (Error LED) remains OFF 3 seconds after initial power up.
3.Verify that Link LED’s are ON for connected ports.
4.Verify straight through cabling used between stations.
5.Verify crossover cabling used between switches or repeaters (non
6.Verify that cabling is Category 5 for 100Mbit Operation.
7. Verify TX is connected to far end RX and vise versa (405FX/FXE only).
SUPPORT
Contact
TEL:
FAX:
FCC STATEMENT
This product complies with Part 15 of the
Operation is subject to the following conditions:
(1)This device may not cause harmful Interference
(2)This device must accept any interference received, including interference that may cause undesired operation.
(Revised | 13 |