ELECTRIC TROUBLE SHOOTING

27

SYMPTOM

PROBLEM

TEST SOLUTION

 

 

 

 

 

 

Flames are con- sistently too large or too small. Carboning occurs.

Unit is over-fired or under- fired.

A B

- check pressure readings:

Inlet pressure can be checked by turning screw (A) counter-clock- wise 2 or 3 turns and then placing pressure gauge tubing over the test point. Gauge should read 7" (minimum 4.5") water column for natural gas or 13" (11" minimum) water column for propane. Check that main burner is operating on "HI".

Outlet pressure can be checked the same as above using screw (B). Gauge should read 3.5" water column for natural gas or 10" water column for propane. Check that main burner is operating on "HI".

AFTER TAKING PRESSURE READINGS, BE SURE TO TURN SCREWS CLOCKWISE FIRMLY TO RESEAL. DO NOT OVERTORQUE. Leak test with a soap and water solution.

 

Flames are very

 

Door is ajar

- Close door and secure the 2 latches.

 

 

aggressive.

 

 

 

 

 

 

 

Main burner flame

Blockage in vent.

-

remove blockage. In really cold conditions, ice buildup may occur

 

is a blue,

lazy,

 

 

on the terminal and should be removed as required.

 

transparent flame.

 

 

 

 

 

 

Incorrect installation.

-

refer to Figure 23 to ensure correct location of storm collars.

 

 

 

 

 

Carbon is being Air shutter has become

-

ensure air shutter opening is free of lint or other obstructions.

 

deposited

on

 

blocked

 

 

 

 

glass, logs or com-

 

Flame is impinging on the

-

check that the logs are correctly positioned.

 

bustion chamber

 

logs or combustion cham-

-

open air shutter to increase the primary air.

 

surfaces.

 

 

ber.

-

check the input rate: check the manifold pressure and orifice size

 

 

 

 

 

 

 

 

 

as specified by the rating plate values.

 

 

 

 

 

- check that the door gasketing is not broken or missing and that the

 

 

 

 

 

seal is tight.

 

 

 

 

 

- check that both 4" and 7" vent liners are free of holes and well

 

 

 

 

 

sealed at all joints.

 

 

 

 

 

- check that minimum rise per foor has been adhered to for any

 

 

 

 

 

horizontal venting.

 

 

 

 

 

 

 

White / grey film

 

Sulphur from fuel is being

-

clean the glass with a recommended gas fireplace glass cleaner.

 

forms.

 

 

deposited on glass, logs or

DO NOT CLEAN GLASS WHEN HOT.

 

 

 

 

combustion chamber sur-

If deposits are not cleaned off regularly, the glass may become

 

 

 

 

faces.

permanently marked.

 

 

 

 

 

 

 

 

Remote

wall

 

Wall switch is mounted up-

- reverse.

 

switch is in "OFF" side down

 

 

 

 

position;

main

 

Remote wall switch is

- replace.

 

burner comes on

 

grounding.

 

 

 

 

when gas knob is

 

 

 

 

 

Remote wall switch wire is

- check for ground (short); repair ground or replace wire.

 

turned to "ON" po-

 

grounding.

 

 

 

 

sition.

 

 

 

 

 

 

 

 

 

Faulty valve.

- replace.

 

 

 

 

ELECTRIC TROUBLE SHOOTING

All but flame light

-

Light bulbs are loose or

-

Remove the access panel and change or tighten light bulbs.

works

 

have burned out.

 

 

 

Flame light, but no

-

Flame generator is

-

Replace the batteries and check the power source.

movement in the

 

defective.

-

Consult your local dealer.

 

flame

-

Flame generator has

-

Remove the access panel and check to make sure the flame

 

 

 

come loose.

 

generator bracket is secured to the motor with the rubber tube.

Remote control

-

Dead batteries.

-

Make sure batteries are charged.

not working

-

No power to the unit.

-

Make sure main power is on.

 

 

-

Power turned off.

-

Turn on manual power switch.

 

 

-

Power button on control

-

Make sure the power button is on REMOTE setting.

 

 

 

panel is in the manual or

 

 

 

 

 

 

off position.

 

 

 

 

Fireplace will not

-

Breaker or fuse has blown. -

Reset breaker switch or replace fuse.

 

turn on.

-

Main switch is in the off

-

Consult your local dealer.

 

 

 

position

-

Make sure main power switch is turned to the on position.