Napoleon Fireplaces GE38PT-M, GE38NT-M manual Top Exit Vertical Termination, 90 V1H3 H H1

Models: GE38PT-M GE38NT-M

1 28
Download 28 pages 63.44 Kb
Page 10
Image 10
TOP EXIT VERTICAL TERMINATION

10

TOP EXIT VERTICAL TERMINATION

when (Ht) < (Vt)

Example 4:

 

Simple venting configurations

 

 

FIGURE 10

FIGURE 11

V2

 

90°

 

 

90° V1 H3 90° V1 H3  90° 90°

Manual backgroundH

H1 Manual background 2Manual backgroundManual background 90°

See graph to determine the required vertical rise VT for the required horizontal run HT.

REQUIRED

VERTICAL RISE

IN FEET

VT

HORIZONTAL VENT RUN PLUS OFFSET IN FEET HT

The shaded area within the lines represents acceptable values for HT and VT .

For vent configurations requiring elbows, the following for- mulas apply:

Formula 1: HT < VT

Formula 2: HT + VT < 40 feet

V1

=5 ft

V2

=10 ft

VT

= V1 + V2 = 5 + 10 = 15 ft

H1

=1 ft

H2

=3 ft

H3

=2.5 ft

HR

= H1 + H2 + H3 = 1 + 3 + 2.5 = 6.5 ft

HO

= .03(four 90° elbows - 90°)

 

= .03(90 + 90 + 90 + 90 - 90) = 8.1 ft

HT

=HR + HO = 6.5 + 8.1 = 14.6 ft

HT + VT = 14.6 + 15 = 29.6 ft

Formula 1: HT < VT 14.6 < 15

Formula 2: HT + VT < 40 feet

29.6 < 40

Since both formulas are met, this vent configuration is ac- ceptable.

W415-0429 / C / 11.04.05

Page 10