Napoleon Fireplaces GE38NT-M Adjustments, Pilot Burner Adjustment, Venturi Adjustment, 1/16, 3/16

Models: GE38PT-M GE38NT-M

1 28
Download 28 pages 63.44 Kb
Page 23
Image 23
ADJUSTMENTS

23

ADJUSTMENTS

PILOT BURNER ADJUSTMENT

Adjust the pilot screw to provide properly sized flame. Turn in a clockwise direction to reduce the gas flow.

PILOT SCREW FIGURE 54

FIGURE 55

VENTURI ADJUSTMENT

Air shutters have been factory set open according to the chart below:

 

AIR SHUTTER

 

 

NG

1/16"

LP

3/16"

These settings are for the maximum horizontal vent run. Adjustment may be required depending on fuel type, vent configuration and altitude.

Closing the air shutter will cause a more yellow flame, but can lead to carboning.

Opening the air shutter will cause a more blue flame, but can cause flame lifting from the burner ports. The flame may not appear yellow immediately; allow 15 to 30 min- utes for the final flame colour to be established.

FIGURE 56

Air shutter adjustment must only be done by a

qualified installer!

VENTURI

COVER

FIGURE 57

1.Remove the front central panel to access the venturi housing.

2.Remove the 2 screws that secure the cover to the venturi housing, taking care not to damage the gasket.