Napoleon Fireplaces GE38NT-M, GE38PT-M Typical Vent Installations, Special Vent Installations

Models: GE38PT-M GE38NT-M

1 28
Download 28 pages 63.44 Kb
Page 7
Image 7
TYPICAL VENT INSTALLATIONS

7

TYPICAL VENT INSTALLATIONS

For optimum performance, it is recommended FIGURES 3 that all horizontal runs have a 1 inch rise per foot.

When terminating vertically, the vertical rise is a minimum 36 inches and a maximum 40 feet from the centre of the fireplace flue outlet.

40 FT MAX

3 FT MIN

7"

SPECIAL VENT INSTALLATIONS

PERISCOPE TERMINATION

Use the GD201 periscope kit to locate the air termination above grade. The periscope must be installed so that when final grading is completed, the bottom air slot is located a minimum of 12 inches above grade. The maximum allow- able vent length depends on the fireplace, as illustrated.

FIGURE 4

VENTING APPLICATION FLOW CHART

HORIZONTAL TERMINATION

VERTICAL TERMINATION

vertical rise is equal toorgreaterthanthe horizontal run

horizontal run + ver- tical rise to maxi- mum of 40 feet

vertical rise is less than horizontal run

horizontal run + ver- tical rise to maxi- mum of 24.75 feet

4.2times the verti- cal rise equal to or greater than the horizontal run

vertical rise is equal toorgreaterthanthe horizontal run

horizontal run + ver- tical rise to maxi- mum of 40 feet

vertical rise is less than horizontal run

horizontal run + ver- tical rise to maxi- mum of 40 feet

3 times the vertical rise equal to or greater than the horizontal run