Napco Security Technologies F-TPG manual Fire Protection, Fire-ZoneTrouble

Models: F-TPG

1 28
Download 28 pages 61.88 Kb
Page 15
Image 15
FIRE PROTECTION*

FIRE PROTECTION*

If a fire is detected, the siren will sound a distinct pulsating tone and the FIRE indicator on the Ga- rage Touchpad will be flashing. If a Fire Alarm does occur:

 

FIRE

* Note: This feature may not apply to your system. Consult your installer to determine if your system includes fire protection.

 

 

 

 

1

If a fire is in progress, evacuate the premises immediately! Call the Fire Department from an outside phone.

2

 

If there is no evidence of a fire, press SILENCE OR insert your F-IFOB key into the Garage Touchpad.

 

The siren will silence, and FIRE on the Garage Touchpad will stop flashing, and light steady.

 

 

 

 

 

3

 

Determine which device went into alarm. If you are protected by smoke detectors, the light on the

 

active detector will be lit. Once it is determined which smoke detector is in alarm, press SILENCE to

 

reset the smoke detector.

 

 

 

4

FIRE

If the Fire Zone has reset properly, the FIRE light should go out in approximately 30 seconds. If it

does not go out, press SILENCE again in a few minutes. If it still does not go out, call for service.

 

Fire-Zone Trouble

TBL

The system is constantly monitoring the Fire Zone to insure the connections to the protective de- vices are in good working order.

If a problem on a Fire Zone is detected, a System Trouble will display. The sounder will activate and the Trouble TBL light will blink 7 times.

Press the SILENCE button to silence the sounder. Call for service immediately.

15

Page 15
Image 15
Napco Security Technologies F-TPG manual Fire Protection, Fire-ZoneTrouble