￿￿System Troubles

The GEM-P400 is constantly monitoring its own components, as well as all critical services, such as AC power and the telephone line, to insure that it is always ready to provide the protection for which it was designed. When a system trouble does occur, it will

caution you by lighting thelight and beeping the keypad buzzer.

If you cannot immediately clear the system trouble, the system can still be used. Simply press ￿followed by ￿to view the trouble as described below, and then arm the system.

To determine the nature of the trouble, press ￿followed by ￿, count the number of keypad beeps and observe the number of the illuminated zone. Refer to the following table to determine the cause of the trouble. If there is more than one trouble to view,

pressing ￿will scroll to the next trouble, and then exit the TROUBLE

mode if there are no more troubles to view.

 

 

 

 

 

Keypad Beeps or

Zone light

System Trouble

 

Action

Flashes

ON

Condition

 

 

 

 

 

 

1 Beep

1

AC Power Failure

This trouble will occur if AC power is not present. Make sure system transformer is

 

 

 

plugged into AC receptacle and check the circuit breaker, otherwise call installing

 

 

 

company for service.

 

 

 

 

 

1 Beep

2

Low Battery

If there has been a recent power failure, the battery may be partially depleted and

 

 

 

must be recharged by the control panel. If the trouble does not go away in 24 hours,

 

 

 

call installing company for service.

 

 

 

 

1 Beep

3

Communication

The system was not able to report to central station. If this is due to a temporary inter-

 

 

Failure

ruption in the telephone service, the trouble can be cleared when the service is re-

 

 

 

stored by pressing ￿followed by￿again to view the trouble, and and then

 

 

 

pressing ￿to exit. Otherwise, call installing company for service.

 

 

 

 

1 Beep

4

Telephone Line Cut

The telephone line has failed. If telephone service has been temporarily interrupted,

 

 

 

the trouble will clear it is when restored. Otherwise, call installing company for service.

 

 

 

 

2 Beeps

1

Bell/Siren Trouble

There is a problem with the Bell or Siren. Call installing company for service.

11

Oi230a

Tuesday, September 16, 1997 08:26

page 11

 

Page 11
Image 11
Napco Security Technologies GEM-P400 manual System Troubles, Mode if there are no more troubles to view

GEM-P400 specifications

Napco Security Technologies GEM-P400 is a state-of-the-art security control panel designed for residential and commercial applications. This robust system offers a comprehensive suite of features that enhance security and streamline system management.

One of the standout features of the GEM-P400 is its ability to support a wide range of security devices. It can integrate seamlessly with various sensors, alarms, and cameras, providing users with flexibility and scalability in their security solutions. With the capacity to manage up to 40 zones, the GEM-P400 ensures that every aspect of a property is covered, from doors and windows to motion detectors.

The GEM-P400 utilizes advanced communication technologies, including IP and cellular connectivity. This dual-path communication method ensures that users receive real-time alerts and notifications, even during a power outage or if the phone line is cut. This redundancy is crucial for maintaining security and peace of mind.

Another notable characteristic of the GEM-P400 is its user-friendly interface. The panel is equipped with an intuitive keypad that allows for easy navigation and operation. Users can quickly arm or disarm the system, adjust settings, and check system status with minimal hassle. Furthermore, the system supports remote access via mobile apps, enabling users to monitor their security setup from anywhere in the world.

The GEM-P400 also offers programmable functions, providing customization options to fit various user needs. This includes the ability to configure specific alarm settings, schedules, and access levels for different users. Such flexibility ensures that whether it’s a family home or a business, the security setup can be tailored to meet specific requirements.

Additionally, Napco Security Technologies emphasizes the importance of reliable performance. The GEM-P400 is built with durability and longevity in mind. It incorporates advanced hardware that ensures stable operation, reducing the likelihood of malfunctions and improving overall reliability.

In summary, the GEM-P400 from Napco Security Technologies distinguishes itself as a feature-rich, flexible, and robust security panel. Its integration capabilities, dual-path communication, user-friendly interface, and advanced programmability make it an excellent choice for both residential and commercial security needs. With its commitment to quality and performance, Napco Security Technologies continues to be a trusted name in the security technology industry.