3.The access panel can be removed by taking out the 8 #10 self taping screws. A 5/16" nut driver will be required to complete this job. Unplug wires from the thermal switch on the panel. See FIGURE 15.

4.Remove the securing wingnut from the blower mounting bracket, slide the bracket to the right and rotate the left side of the assembly out of the cavity to clear the blower motor. Disconnect the two wires from the blower motor. Remove the ground wire from the blower mounting bracket, then the assembly can be taken out of the rear cavity through the access door opening.

5.Remove the 3 screws that hold the blower to the mount- ing bracket. Service or replace the blower as required.

GROUND STUD SECURING

WINGNUT TAB

9

1150 BLOWER INSTALLATION

1.Remove the knock-out from the back of the fireplace.

2.Install the blower and housing as shown using the 4 screws supplied.

FIGURE 19

FIGURE 16

6.Reinstall the blower assem- bly making sure the blower bracket is seated under the se- curing tab. FIGURE 16. Reattach the wire connectors. FIGURE 17.

7.Replace the gasket on the ac- cess door. To replace the ac- cess panel, reverse Step 3 .

8.Replace the bricks into the firebox. Reinstall the door.

WIRES

FIGURE 17

3.Loosen the thermodisc bracket (2 screws) and slide the bracket forward until the thermodisc is touching the rear firebox and secure.

1150 FEATURES

FIGURE 20

1401 BLOWER SERVICE OR REPLACEMENT

1.Turn off all electrical power to the insert. Remove the glass door and set aside in a safe place.

2.Remove the two screws from the outer edge of the side panel(s).

3.Push the side panel toward the door and pull away from the insert, releasing the panel from the keyed slot.

4.Service or replace the blower(s) as required.

5.Re-install the side panel(s) by reversing the procedure.

G

HEATB

SENSOR

W

FIGURE 18

Pot

Fender

Wood

Storage

(intended for

short term use)

LID LIFTER

HOOK

Remove the screw, as illustrated, from the preferred side of the stove rear. Secure the lid lifter hook, as illustrated, facing out to the side, or bend it towards the back.