INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE

1

INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCECONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE

INSTALLATIONCONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE

AND OPERATION

INSTRUCTIONSINSTALLATION

CERTIFIED UNDER U.S. ENVIRONMENTAL PROTECTION AGENCY (E.P.A.) JULY 1990 AND THE OREGON DEPARTMENT OF ENVIRONMENTAL QUALITY (D.E.Q.) PARTICULATE EMISSION STANDARDS BY E.E.M.C THESE STOVES HAVE BEEN TESTED AND LISTED BY INTERTEK TESTING SERVICES TO STANDARDS: CSA B366.2, ULC S627, UL 1482. MODEL 1100 HAS BEEN TESTED AND LISTED FOR INSTALLATION IN MOBILE HOMES.

EPA 1100, 1100L, 1100C, 1150,

1400, 1400L, 1450 & 1900

FREE STANDING MODELS

EPI 1101, 1402

INSERT MODEL

SAFETY INFORMATION

! WARNING

If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage, bodily injury or even death. Please read entire manual before you install and use your fireplace.

This fireplace has not been tested with an unvented gas log set. To reduce risk of fire or injury, do not install an unvented gas log set into the fireplace.

- This fireplace can be very hot when burning.

- Combustible materials such as firewood, wet clothing, etc. placed too close can catch fire. - Children and pets must be kept from touching the fireplace when it is hot.

- The chimney must be sound and free of cracks. Before installing this unit, contact the local building or fire authority and follow their guidelines.

-Operate only with the door tightly closed.

-Burn wood behind the log retainer directly on the firebricks.

-Do not use an elevated grate or otherwise raise the fire.

- At least 14 square inches of outside air must be admitted to the room or directly to the unit through a 4” diameter pipe.

- This fireplace is designed to burn natural wood only. Higher efficiencies and lower emissions generally result when burning air dried seasoned hardwoods, as compared to softwoods or to green or freshly cut hardwoods.

-Do not start a fire with chemicals or fluids such as gasoline, engine oil, etc.

-Do not burn treated wood, coal, charcoal, colored paper, cardboard, solvents or garbage.

-Do not let the fireplace become hot enough for any part to glow red.

-KEEP THE STOVE TOP TEMPERATURE BELOW 700°F (371°C). Attempts to acheieve heat output rates that exceed design specifications can result in steel distortion and damage.

Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada s (705)721-1212 s fax(705)722-6031

www.napoleonfireplaces.coms ask@napoleon.on.ca