Napoleon Fireplaces GDS 50-N TABLE of CONTENTS, Please Retain This Manual For Future Reference

Models: GDS 50-P GDS 50-N

1 24
Download 24 pages 47.44 Kb
Page 2
Image 2
TABLE of CONTENTS

2

TABLE of CONTENTS

Pg 2-4

INTRODUCTION

Pg 14

GAS INSTALLATION

 

Warranty

15-16 FINISHING

 

General Instructions

 

Door Opening & Closing

 

General Information

 

 

 

Louvre & Trivet Installation

 

Care of Glass & Plated Parts

 

 

 

Mantle Clearances

5

LOCATION & CLEARANCES

 

 

Log Placement

6-11

DIRECT VENT SPECIFICS

17-18 OPERATION / MAINTENANCE

MODEL GDS50

 

Spill Switch

 

Vent Lengths/Air Terminal Locations

 

Turbo Burner

 

Special Installation Example

 

Operating Instructions

 

Offset Installation Example

 

Maintenance

 

Wall & Ceiling Protection

19

REPLACEMENT BLOWER

 

Horizontal Venting Installation

20

ADJUSTMENTS

 

Vertical Venting Installation

 

Stove Vent Connection

 

Pilot Burner Adjustment

 

Mobile Home Installation

 

Venturi Adjustments

12-14 B-VENT SPECIFICS

21-22 REPLACEMENTS

MODEL GS50

 

Ordering Replacement Parts

 

Chimney Installation

 

Terminal Kits

 

 

Accessories

 

'B' Vent Installation

 

 

 

Replacement Parts

 

Adding Vent Sections

 

 

23-24 TROUBLE SHOOTING GUIDE

 

Flashing and Storm Collar Installation

'B' Vent Adaptations

Combustion Air

PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE

WARNING

The stove is a vented gas-fired heater. Do not burn wood or other materials in this stove.

Adults and especially children should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. Supervise young children when they are in the same room as the stove.

Due to high temperatures, the stove should be located out of traffic and away from furniture and draperies.

Clothing or other flammable material should not be placed on or near the stove.

Any safety screen or guard removed for servicing must be replaced prior to operating the stove.

It is imperative that the control compartments, burners and circulating blower and its passageway in the stove and venting system are kept clean. The stove and its venting system should be inspected before use and at least annually by a qualified service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. The stove area must be kept clear and free from combustible materials, gaso line and other flammable vapours and liquids.

Under no circumstances should this stove be modified.

This stove must not be connected to a chimney flue pipe serving a separate solid fuel burning appliance.

Do not use this stove if any part has been under water. Immediately call a qualified service technician to inspect the stove and to replace any part of the control system and any gas control which has been under water.

Do not operate the stove with the glass door opened, cracked or broken. Replacement of the glass should be done by a licensed or qualified service person.

Do not strike or slam shut the stove glass door.

This fireplace uses and requires a fast acting thermocouple. Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd.

Adults and especially children should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. Keep young children and animals away when the fireplace is hot.

W415-0098 / C / 04.19.06

Page 2
Image 2
Napoleon Fireplaces GDS 50-N, GDS 50-P manual TABLE of CONTENTS, Please Retain This Manual For Future Reference