24

SYMPTOM

PROBLEM

TEST SOLUTION

 

 

 

Main burner goes out; pilot goes out.

REFER TO "MAIN BURNER GOES OUT; PILOT STAYS ON"

 

 

Vent re-circulating

-

check joint seals and installation.

 

 

(MODEL GDS50 ONLY)

 

 

 

 

Thermocouple shorting or

- loosen and tighten thermocouple

 

faulty.

-

clean thermocouple and valve connection.

 

 

 

-

replace thermocouple.

 

 

 

-

replace valve.

 

 

 

 

 

 

Exhaust

fumes

Fireplace is spilling.

- check all seals.

smelled in

room,

 

 

headaches.

 

 

 

Carbon is being de- posited on glass, logs or combustion chamber surfaces.

Air shutter has become

-

ensure air shutter opening is free of lint or other obstruc-

blocked

tions.

 

 

 

Flame is impinging on the

-

check that the logs are correctly positioned.

logs or combustion chamber.

-

open air shutter to increase the primary air.

 

-

check the input rate: check the manifold pressure and orifice

size as specified by the rating plate values.

- check that the door gasketing is not broken or missing and that the seal is tight.

- check that both vent liners are free of holes and well sealed at all joints.

- check that minimum rise per foot has been adhered to for any horizontal venting.

Blower does not turn

Blower high limit switch has

on.

been activated.

Turn blower switch on, turn turbo rear burner off and front burner to low. When blower turns on, re-adjust burners.

Door sticking.

Dirt / dust adheres to the

 

hinges; is heated and burns

 

causing sticking.

- lift door from its hinges. Lubricate with high-temp dry graph- ite only.

NOTE: Due to the high temperatures that the hinges experi- ence, wet lubricants such as oil and WD40 will cause the hinge to seize and are therefore not suitable.

MODELS GDS50 ONLY: Main burner flame is

ablue, lazy, transpar- ent flame.

Blockage in vent.

- remove blockage. In really cold conditions, ice buildup may

 

occur on the terminal and should be removed as required.

Incorrect installation.

- refer to Figure 22 to ensure correct location of storm collars

 

(Model GDS50 only).

White / grey film

Sulphur from fuel is being de-

- clean the glass with a recommended gas fireplace glass

forms.

posited on glass, logs or com-

cleaner. DO NOT CLEAN GLASS WHEN HOT.

 

bustion chamber surfaces.

If deposits are not cleaned off regularly, the glass may be-

 

 

come permanently marked.

 

 

 

 

 

 

 

 

 

W415-0098 / C / 04.19.06

Page 24
Image 24
Napoleon Fireplaces GDS 50-N, GDS 50-P manual Model GDS50 only