NAILING TAB INSTALLATION
To install the fireplace face flush with the finished surface, position the framework to accomodate the thickness of the finished surface. Use 4 self tapping screws to secure the nailing tabs to the 2 x 4’s. Cover the nailing tabs with your finishing material.
9
CLEARANCES TO COMBUSTIBLES
MAINTAIN THESE MINIMUM CLEARANCES TO COMBUSTIBLES:
Fireplace framing - 6” to top
-0” to
FIGURE 14
ELECTRICAL CONNECTION
CAUTION
Risk of Electric Shock!
Control and valve operate with 120v.
Do NOT use the fireplace if any part has been under water. Call a qualified service technician IMMEDIATELY to have the fireplace inspected for damage to the electrical circuit.
HARD WIRING CONNECTION
It is necessary to hard wire this fireplace. Permanently framing the fireplace with an enclosure, requires the fireplace junction box to be hardwired.
This fireplace must be electrically connected and grounded in accordance with local codes. In the absence of local codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or the ANSI/NFPA
NATIONAL ELECTRICAL CODE in the UnitedFIGURE 15 States.