OPERATING INSTRUCTIONS

11

OPERATING INSTRUCTIONS

When lit for the first time, the fireplace will emit a slight odour for a few hours. This is a normal temporary condition caused by the curing of paints and lubricants used in the manufacturing process and will not occur again. Simply open a window to sufficiently ventilate the room.

After extended periods of non-operation such as following a vacation or a warm weather season, the fireplace may emit a

slight odour for a few hours. This is caused by dust particles in the heat exchanger burning off. Open a window to sufficiently ventilate the room.

Purge all gas lines with the glass door of the fireplace open. Assure that a continuous gas flow is at the burner before closing the door.

FOR YOUR SAFETY READ BEFORE LIGHTING:

 

WHAT TO DO IF YOU SMELL GAS:

A.This fireplace is equipped with an ignition device which automatically lights the burner. Do not try to light by hand.

B.Before operating, smell all around the fireplace area for gas and next to the floor because some gas is heavier than air and will settle on the floor.

C.Do not use this fireplace if any part has been under water. Immediately call a qualified service technician to inspect the fireplace and replace any part of the control system and any gas control which has been under water.

Turn off all gas to the fireplace.

Open windows.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbour’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

LIGHTING INSTRUCTIONS

1.STOP! Read the safety information located above.

2.Turn off all electric power to the fireplace.

3.This fireplace is equipped with an ignition device which automatically lights the burner. Do not try to light by hand.

4.Remove the glass door.

5.Wait five (5) minutes to clear out any gas. If you smell gas including near the floor STOP! Follow “B” in the above safety information on this label. If you don’t smell gas go to the next step.

6.Replace the glass door.

7.Turn on all electric power to the fireplace.

8.Turn the fireplace switch to the ON position.

9.If fireplace will not operate, follow instructions “To Turn Off Gas” and call your service technician or gas supplier.

FIGURE 21

TO TURN OFF GAS

1. Turn the fireplace switch to the OFF position.

3. Turn manual shut-off valve clockwise

to off.

2. Turn off all electrical power to the fireplace if service is

Do not force.

 

to be preformed.

 

 