CARE OF GLASS, AND PLATED PARTS

5

CARE OF GLASS, AND PLATED PARTS

WARNING

DO NOT SUBSTITUTE MATERIALS.

USE CARE WHEN HANDLING GLASS COMPONENTS DO NOT STIKE, OR SLAM SHUT.

DO NOT OPERATE WITH BROKEN GLASS.

The glass is 3/16” ceramic glass available from your Napoleon® / Wolf Steel Ltd. dealer. Clean the glass after the first 10 hours of operation with a recommended gas fireplace glass cleaner. Thereafter clean as required. DO NOT CLEAN GLASS WHEN HOT! Do not use abrasive cleaners to clean plated parts. Buff lightly with a clean dry cloth. If the glass is not kept clean permanent discolouration and / or blemishes may result.

VENTING

VENTING LENGTHS

For safe and proper operation of the fireplace follow the venting instruction exactly.

The GT8N/P must be terminated horizontally only.

The vent connection to the fireplace can be viewed by removing the baffle from the top, inside of the firebox.

Vent lengths that pass through unheated spaces (attics, garages, crawl spaces) should be insulated with the insulation wrapped in a protective sleeve to minimize condensation.

Venting terminals shall not be recessed into a wall or siding.

Use only Wolf Steel Ltd. flexible vent components with the Wolf Steel Ltd. GD179 termination kit.

With flexible venting, in conjunction with the GD178 wall terminal kit, use either the 5 foot vent kit GDT5 or the 10 foot vent kit GDT10. These kits allow for extended horizontal venting of the fireplace.

The maximum allowable vent length is 10’ feet using flexible venting. The maximum number of allowable 3” vent connections is one (excluding the fireplace and the air terminal connections).

For optimum flame appearance and fireplace performance, keep the vent length and number of elbows to a minimum.

The air terminal must remain unobstructed at all times. Examine the air terminal at least once a year to verify that it is unobstructed and undamaged.

Horizontal runs may have a 0 inch rise per foot in all cases when venting as illustrated in Figures 2a, 2b ,and 2c. For optimum performance, it is recommended that all horizontal runs have a minimum ¼ inch rise per foot.

When venting, the horizontal run must be kept to a minimum of 4” inches or a maximum of 72”. If a 72” horizontal run is required, the fireplace must have a minimum vertical rise immediately off the fireplace of 18”. Figures 2a, 2b, and 2c.

Do not allow the inside liner to bunch up on horizontal runs and elbows. Keep it pulled tight. A 3/4” air gap between the inner and outer liner all around is required for safe operation.

Use firestop spacer (W500-0358) when penetrating interior walls and ceilings.

VENTING 8” VENTING LENGTHS

FIGURE 2a

 

84”

MAXIMUM

72” MAX.

4” MIN.

 

MAX.

HORIZONTAL

 

 

 

 

 

24” MAX.

 

 

18”

 

 

 

 

 

 

8”

MAXIMUM

 

 

 

VERITICAL

 

 

 

 

 

 

FIGURE 2b

FIGURE 2c

W415-0619 / A / 08.09.07

Page 5