FIGURE 35

14

GAS INSTALLATION

GAS INSTALLATION

Read the section on opening the door in "Finish- ing" prior to proceeding to prevent damaging the unit.

Bring the gas line to the stove through either the opening in the pedestal back or through the floor directly beneath the pedestal base.

MODELS GDS50 AND GS50 ONLY

Install rigid black pipe or ½" type L copper tubing with a shut-off valve to the stove.

Seal and tighten the gas line securely to the flex connector supplied.

Do not kink the flexible connector.

Mark the two appropriate boxes on the rating plate la- bel. One to indicate the model type depending on the in- stallation (direct vent or B-vent). Mark the second box to indicate the altitude type and the type of fuel being used (natural gas or propane).

CERTIFIEDUNDERCSA2.33A-M98,ANSIZ21.88A-1998

HOMOLOGUESELONLESNORMESFOYERDECHAUFFAGE

VENTEDGASFIREPLACEHEATERAPPLIANCEMUSTBE

AU GAZ AVEC EVACUATION CET APPAREIL DOIT ETRE

INSTALLED USING BURNER KIT : GDS50BN-KT,

INSTALLE EN UTILISANT UN ENSEMBLE DU BRULEUR:

OR GDS50BP-KT.

 

 

GDS50BN-KT,OUGDS50BP-KT.

CDVS500 -N

GDS50 -N

 

GDS50 -P

CDVS500 -P

CS500-N

GS50-N

 

 

GS50-P

CS500-P

0-2000ft (0-610m)

2000-4500ft (610-1370m) ALTITUDE/ELEVATION

40,000 BTU/h

2000-4500ft (610-1370m)

44,000 BTU/h

40,000 BTU/h

 

INPUT/ALIMENTATION

21,000 BTU/h

36,000 BTU/h

20,000 BTU/h

18,000 BTU/h

REDUCED INPUT / ALIMENTATION REDUITE30,400 BTU/h

18,000 BTU/h

33,000 BTU/h

30,000 BTU/h

 

OUTPUT (MODEL GDS50) RENDEMENT 30,000 BTU/h

27,400 BTU/h

31,200 BTU/h

28,400 BTU/h

 

OUTPUT (MODEL GS50) RENDEMENT

#53

26,400 BTU/h

#34

#36

 

FRONT ORIFICE / INJECTEUR AVANT

#57

#53

#43

#45

 

TURBO ORIFICE / INJECTEUR TURBO

 

#59

B-VENT MODEL GS50 ONLY

Attach one lead from the spill switch (white wire) to terminal #3 located on the gas valve and the other (black) on/off switch lead to valve terminal #1.

FIGURE 34

Attach the B-Vent label, shown below, in the control area of the appliance.

ATTACH THIS LABEL IN THE CONTROL AREA OF THE FIREPLACE.

THIS FIREPLACE HAS BEEN CONVERTED TO A ‘B’VENT MODEL.

ATTACHEZ CET ETIQUETTE DANS LA REGION DE CONTROLE DU FOYER.

CE FOYER A ETE CONVERTI A UN MODELE A SYSTEME D’EVACUATION ‘B’.

ws-385-160

Check for gas leaks by brushing on a soap and water solu- tion. DO NOT USE OPEN FLAME.

DIRECT VENT MODEL GDS50

Disconnect the existing wires from terminals 1 and 3 (from the on/off switch) and replace with the leads from the wall switch/millivolt thermostat.

B-VENT MODEL GS50

Disconnect the existing on/off switch wire from terminal 1

*ALTITUDEDOWNRATING CONDITIONS APPLY TO CANADA ONLY

LES CONDITIONS DE BAISSE D’EVALUATION SELON L’ALTITUDES’APPLIQUENTAUCANADASEULEMENT MANIFOLD PRESSURE: 3.5 INCHES W.C. (NG) / 10 INCHES W.C.(LP) PRESSION AU COLLECTEUR: 3.5" D'UNE COLONNE D'EAU(GN)

10" D'UNE COLONNE D'EAU (PG)

MIN SUPPLY PRESSURE: 4.5" W.C.(NG) / 11" W.C. (LP)

PRESSIOND'ALIMENTATIONMIN:4.5"D'UNECOLONNED'EAU

11" D'UNE COLONNE D'EAU (PG)

MAX. SUPPLY PRESSURE: 7" W.C. (NG) / 13" W.C. (LP)

PRESSIOND'ALIMENTATIONMAX:7"D'UNECOLONNED'EAU

13" D'UNE COLONNE D'EAU (PG)

FOR USE WITH GLASS DOORS CERTIFIED WITH THIS UNIT ONLY.

UTILISER AVEC LES PORTES VITREES HOMOLOGUEES SEULEMENTAVECCETTEUNITE.

WARNING: DONOTADDANYMATERIALTOTHEAPPLIANCE, WHICHWILLCOMEINCONTACTWITHTHEFLAMES,OTHER THANTHATSUPPLIEDBYTHEMANUFACTURERWITHTHEAP- PLIANCE.

AVERTISSEMENT: N'AJOUTEZ PAS A CET APPAREIL AUCUN MATERIAU DEVANT ENTRER EN CONTACT AVEC LES FLAMMES AUTRE QUE CELUI QUI EST FOURNI AVEC CET APPAREIL PAR LE FABRICANT.

MINIMUMCLEARANCETOCOMBUSTIBLEMATERIAL/ DEGAGEMENTSMINIMAUXDESMATERIAUXCOMBUSTIBLES:

A

7"

D 17½"

B

2"

E 6¼"

C

1"

F 9½"

20"TOCEILINGFROMSTOVETOP 20"ENTRELEDESSUSDUFOYERETLEPLAFOND ELECTRICAL RATING / CLASS.: 115V 1.5AMP 60HZ

B-VENT MODELS GS50/CS500 APPROVED FOR BED-

ROOM,&BEDSITTINGROOMINSTALLATION. HOMOLOGUE POUR INSTALLATION DANS UNE CHAMBRE A COUCHER, & UN STUDIO.

STEADY STATE EFFICIENCY (NG): 71% FAN OFF / 77% FAN ON

STEADY STATE EFFICIENCY (LP): 73% FAN OFF / 78% FAN ON

EFFICACITE CONSTANTE (GN): 71%VENT.ARRETE 77%VENT.FONCTIONNE

EFFICACITECONSTANTE(GP): 73%VENTILATEURARRETE 78% VENTILATEUR FONCTIONNE STEADY STATE EFFICIENCY APPLIES TO CANADA ONLY /

L'EFFICACITE CONSTANTE S'APPLIQUENT SEULEMENT AU CANADA.

AFUE (NG/LP) (GN/GP): 64% / 67%

THIS APPLIANCE MUST BE INSTALLED USING AN ADAPTER KITGS-150KT.CETAPPAREILDOITETREINSTALLEENUTILI- SANTUNENSEMBLEADAPTATEURGS-150KT.

DIRECT VENT MODELS GDS50 CDVS500 APPROVED FOR BEDROOM, BATHROOM & BEDSITTING ROOM INSTALLATION. SUITABLE FOR MOBILE HOME INSTALLATION IF INSTALLED IN ACCORDANCE WITH THE CURRENT STANDARD CAN/CSA Z240MH SERIES GAS EQUIPPED MOBILE HOMES, IN CANADA OR IN THE UNITED STATES THE MANUFACTURED HOME CONTRUCTION AND SAFETY STANDARD, TITLE 24 CFR, PART 3280. WHEN THIS US STANDARD IS NOT APPLI- CABLE USE THE STANDARD FOR FIRE SAFETY CRITERIA FOR MANUFACTURED HOME INSTALLATIONS, SITES AND COM- MUNITIES, ANSI / NFPA 501A.

HOMOLOGUE POUR INSTALLATION DANS UNE CHAMBRE A COUCHER, UNE SALLE DE BAIN ET UN STUDIO. APPROPRIE POUR INSTALLATION DANS UNE MAISON MOBILE SI SON IN- STALLATION CONFORME AUX EXIGENCES DE LA NORME CAN/CSA Z240MH SERIE DE MAISONS MOBILES EQUIPEES AU GAZ, EN VIGUEUR AU CANADA OU AUX ETATS-UNIS DE LA NORME DE SECURITE ET DE CONSTRUCTION DE MAISONS MANUFACTUREES, TITRE 24 CFR, SECTION 3280. DANS LE CAS OU CETTE NORME D'ETATS-UNIS NE PEUT ETRE APPLIQUEE, SE REFERER A LA NORME RELATIVE AU CRITERE DE MESURES DE SECURITE CONTRE L'INCENDIE POUR LES INSTALLATIONS DANS LES MAISONS MANUFACTURES, LES SITES ET LES COMMUNAUTES, ANSI/NFPA 501A.

STEADY STATE EFFICIENCY (NG): 75% FAN OFF / 78% FAN ON

STEADY STATE EFFICIENCY (LP): 76% FAN OFF / 79% FAN ON

EFFICACITE CONSTANTE (GN): 75% VENT. ARRETE

78% VENT. FONCTIONNE

EFFICACITE CONSTANTE (GP): 76% VENTILATEUR ARRETE 79%VENTILATEURFONCTIONNE STEADY STATE EFFICIENCY APPLIES TO CANADA ONLY /

L'EFFICACITE CONSTANTE S'APPLIQUENT SEULEMENT AU CANADA.

AFUE (NG/LP) (GN/GP): 65% / 67%

MINIMUM AND MAXIMUM HORIZONTAL VENT LENGTHS ARE 25 INCHES AND 20 FEET RESPECTIVELY. LES LONGUEURS HORIZONTALES MINIMALE ET MAXIMALE SONT 25 POUCES ET 20 PIEDS RESPECTIVEMENT.

THE APPLIANCE MUST BE VENTED USING THE APPROPRI- ATE NAPOLEON VENT KITS. SEE OWNERS INSTALLATION MANUAL FOR VENTING SPECIFICS. PROPER REINSTALLA- TION AND RESEALING IS NECESSARY AFTER SERVICING THE VENT-AIR INTAKE SYSTEM.

L'APPAREIL DOIT EVACUER SES GAZ EN UTILISANT L'ENSEMBLE D'EVACUATION PROPRE A NAPOLEON. REFERER AU MANUEL D'INSTALLATION DE PROPRIETAIRE POUR L'EVACUATION PRECISE. IL EST IMPORTANT DE BIEN REINSTALLER ET RESCELLER L'EVENT APRES AVOIR AS- SURE LE MAINTIEN DU SYSTEME DE PRISE D'AIR.

on the valve and the black switch wire from the terminal block. Replace each connection using the wires from the wall switch/millivolt thermostat. FIGURE 34.

 

WOLF STEEL LTD

NOT FOR USE WITH SOLID FUEL

BARRIE, ONTARIO CANADA

UN COMBUSTIBLE SOLIDE NE DOIT PAS ETRE UTILISE

MADE IN CANADA / FABRIQUE AU CANADA

AVEC CET APPAREIL

SERIAL NUMBER

GDS50

 

NO.DESERIE

 

 

 

WS-385

-181

FIGURE 33

W415-0098 / A / 08.07.03

Page 14
Image 14
Napoleon Grills GS 50-P, GDS 50-N, GDS 50-P, GS 50-N manual GAS Installation

GS 50-P, GDS 50-N, GDS 50-P, GS 50-N specifications

Napoleon Grills offers a remarkable line of outdoor cooking appliances, including the GS 50-N, GDS 50-P, GDS 50-N, and GS 50-P models. These premium gas grills are designed to elevate outdoor cooking experiences, ensuring that every meal cooked is a memorable one.

The GS 50-N model features a large cooking surface, allowing ample space for grilling multiple foods simultaneously. Its stainless steel construction not only enhances durability but also adds a polished, modern aesthetic to outdoor spaces. The Napoleon GS 50-N is equipped with multiple burners, each providing consistent heat distribution for perfectly cooked meals every time.

On the other hand, the GDS 50-P model stands out due to its innovative design and advanced features. Its infrared burner technology allows for high-temperature grilling, perfect for searing meats and achieving restaurant-quality results. With easy-to-use ignition systems, the grill lights quickly, so users can start cooking without hassle.

The GDS 50-N is another excellent addition to Napoleon's grilling lineup. It features a unique modular design, catering to various cooking styles and techniques. From grilling to smoking, this model's versatility allows users to experiment with different flavors and preparations. Its built-in temperature gauge ensures that cooks can monitor heat levels effortlessly.

The GS 50-P combines style and functionality. Its sleek exterior is complemented by cutting-edge features like Napoleon's patented wave cooking grids, which provide even heat retention and prevent smaller foods from falling through the grates. Moreover, each grill arm boasts side shelves for additional workspace, perfect for meal prep or serving.

Safety is also a consideration with these grills. Each model is designed with features such as flame tamers to protect burners from drippings, which can lead to flare-ups. The grease management system simplifies cleanup, allowing users to focus more on cooking rather than maintenance.

Napoleon’s commitment to quality extends to the warranty offered on these models. Users can feel confident in their purchase, knowing they are covered in the event of manufacturing defects.

In conclusion, the GS 50-N, GDS 50-P, GDS 50-N, and GS 50-P from Napoleon Grills represent the pinnacle of outdoor cooking technology, offering features designed to enhance the grilling experience. From durability and safety to innovative designs and advanced cooking options, Napoleon Grills remains a top choice for barbecue enthusiasts and outdoor chefs alike.