Installation

 

 

 

 

 

Table 6 (continued)

 

 

 

 

 

 

 

 

 

 

Electrical Specifications

 

 

 

 

 

 

 

Voltage Designation

 

 

Standard

 

Electric Heat

Model

Code

Voltage

Cycle

Phase

Wire

Full Load Amps

Circuit Breaker

 

AWG /mm

FullLoad Amps (Heating Element kW)

Circuit Breaker

 

AWG /mm

 

 

 

 

 

 

 

 

 

2

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N

440-480

50/60

3

3+PE

20

25

 

10/6.0

41 (9x3 kW)

63

 

8/10.0

 

 

 

 

 

 

 

 

52 (9x4 kW)

63

 

8/10.0

 

 

 

 

 

 

 

 

 

 

 

165

P

380-415

50/60

3

3+N+PE

20

25

 

10/6.0

50 (9x3 kW)

63

 

8/10.0

 

 

61 (9x4 kW)

80

 

6/16.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Q

200-240

50/60

3

3+PE

32

40

 

8/10.0

76 (9x3 kW)

100

 

4/25.0

 

N

440-480

50/60

3

3+PE

19

25

 

10/6.0

42 (9x3 kW)

63

 

8/10.0

 

 

53 (9x4 kW)

63

 

8/10.0

 

 

 

 

 

 

 

 

 

 

 

200

 

 

 

 

 

 

 

 

 

 

 

 

 

P

380-415

50/60

3

3+N+PE

18

25

 

10/6.0

51 (9x3 kW)

63

 

8/10.0

 

 

62 (9x4 kW)

80

 

6/16.0

 

 

 

 

 

 

 

 

 

 

 

 

Q

200-240

50/60

3

3+PE

27

40

 

8/10.0

77 (9x3 kW)

100

 

4/25.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 6