Installation

Supply Programming Table

When programming a supply step on the WE-8, choose between 9 different supply steps. Refer to Table 8.

Supply 1

Turns on the water valve in compartment A of

 

the supply box.

 

 

Supply 2

Turns on the water valve in compartment B of

 

the supply box.

 

 

Supply 3

Turns on the water valve in compartment C of

 

the supply box.

 

 

Supply 4

Activates supply relay 1.

 

 

Supply 5

Activates supply relay 2.

 

 

Supply 6

Activates supply relay 3.

 

 

Supply 7

Activates supply relay 4.

 

 

Supply 8

Activates supply relay 5.

 

 

Supply 9

Activates supply relay 6.

 

 

Table 8

NOTE: The Supply button is button 6.

Supply Relay Configuration (No Wiring)

Supply

Supply

Supply

Supply

Supply

Supply

 

Relay

 

Relay

Relay

Relay

Relay

Relay

6

 

 

1

 

2

 

3

 

4

 

5

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

9

10

11

12

13* 14**

TYPICAL SUPPLY RELAY BOARD CONFIGURATION

 

 

 

 

 

 

 

 

 

 

 

 

CFS7N

 

 

 

 

 

 

 

 

 

 

 

 

CFS7N

*L1 (220 VAC) wire or terminal for remote liquid supply connection.

**L2 common wire (220 VAC) or terminal for remote liquid supply connection.

Figure 35

The supply relay board is set up to give NO Voltage AC output to the respective terminals. It is a dry contact closure of the relay. The voltage applied must be supplied with the jumper configurations. Refer to Figure 36.

Primary 220 Volt Remote Liquid Supply Connection

IMPORTANT: When programming a supply step, supplies 1, 2 and 3 DO NOT control the relays shown on Figure 36. Programming supply 1, 2 or 3 ONLY activates water in compartment A, B or C. Programming supply 4 activates relay 1. Programming supply 5 on the WE-8 will activate supply relay 2, etc. Programming supply 4-9 on the WE-8 will activate supply relay 1-6 on the board, respectively. Refer to Table 8.

Supply

Supply

Supply

Supply

Supply

Supply

 

 

Relay

 

 

Relay

Relay

Relay

Relay

Relay

6

 

 

1

 

2

 

3

 

4

 

 

5

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

9

10

11

12

13*

14**

Pump

 

Pump

 

Pump

 

Pump

 

Pump

Pump

 

 

 

1

 

2

 

3

 

4

 

5

 

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFS8N

 

ELECTRICAL CONNECTION OF THE

 

 

 

 

LIQUID SUPPLY PUMPS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFS8N

*L1 (220 VAC) wire or terminal for remote liquid supply connection.

**L2 common wire (220 VAC) or terminal for remote liquid supply connection.

Figure 36

52

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

9001000

Page 54
Image 54
Alliance Laundry Systems 135, 75, 40, 33, 100, 165, 200, 18, 55 manual Supply Programming Table