Installation
Out-of-Balance Switch
1 |
2 |
CFS501N
1Window
2Probe
Figure 40
The
When the machine goes out of balance by overloading or uneven distribution of the linen, the
IMPORTANT: To guarantee good functioning, the probe should be centered horizontally and vertically at 1/3 from the bottom of the tilt window (when machine drum is empty).
Automatic Lubricator
Only for 75-200 Models
| 1 | 2 |
|
| CFS502N |
1 | Lubricating Device |
|
2 | Screw |
|
Figure 41
The bearing house of the machine is equipped with a lubricating device (1) which automatically lubricates the bearing during one year. Upon delivery of the machine, this lubricator has been brought into use. When replacing, please put on the matching screw (2) in the foreseen opening of the lubricator to activate.
Refer to the machine’s Parts Manual for lubricating device parts in formation.
WARNING
Ignoring this instruction will inevitably cause damage to the bearings and void the warranty!
W492