Installation

Out-of-Balance Switch

1

2

CFS501N

1Window

2Probe

Figure 40

The out-of-balance switch is mounted on the upper right side on the back of the control panel. There is a window around the probe of the switch that is mounted on the movable part of the machine.

When the machine goes out of balance by overloading or uneven distribution of the linen, the out-of-balance switch will interrupt this action to prevent damage to the machine.

IMPORTANT: To guarantee good functioning, the probe should be centered horizontally and vertically at 1/3 from the bottom of the tilt window (when machine drum is empty).

Automatic Lubricator

Only for 75-200 Models

 

1

2

 

 

CFS502N

1

Lubricating Device

 

2

Screw

 

Figure 41

The bearing house of the machine is equipped with a lubricating device (1) which automatically lubricates the bearing during one year. Upon delivery of the machine, this lubricator has been brought into use. When replacing, please put on the matching screw (2) in the foreseen opening of the lubricator to activate.

Refer to the machine’s Parts Manual for lubricating device parts in formation.

WARNING

Ignoring this instruction will inevitably cause damage to the bearings and void the warranty!

W492

54

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

9001000

Page 56
Image 56
Alliance Laundry Systems 75, 40, 33, 100, 135, 165, 200, 18, 55 manual Out-of-Balance Switch, Automatic Lubricator