© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Installation
9001000
54
Out-of-Balance Switch
Figure 40
The out-of-balance switch is mounted on the upper
right side on the back of the control panel. There is a
window around the probe of the switch that is mounted
on the movable part of the machine.
When the machine goes out of balance by overloading
or uneven distribution of the linen, the out-of-balance
switch will interrupt this action to prevent damage to
the machine.
IMPORTANT: To guarantee good functioning, the
probe should be centered horizontally and
vertically at 1/3 from the bottom of the tilt window
(when machine drum is empty).
Automatic Lubricator
Only for 75-200 Models
Figure 41
The bearing house of the machine is equipped with a
lubricating device (1) which automatically lubricates
the bearing during one year. Upon delivery of the
machine, this lubricator has been brought into use.
When replacing, please put on the matching screw (2)
in the foreseen opening of the lubricator to activate.
Refer to the machine’s Parts Manual for lubricating
device parts in formation.
CFS501N
1Window
2Probe
1
2
CFS502N
1Lubricating Device
2Screw
12
Ignoring this instruction will inevitably
cause damage to the bearings and void
the warranty! W492
WARNING