5

DO NOT USE AFLAME TO LEAK TEST.

LEAK TESTING: This must be done before initial use, annually and whenever any gas components are replaced or
serviced. No smoking while performing this test, and remove all sources of ignition. See

Leak TestingDiagram

for areas to
check.
1. Turnall burner controls to off. Turn supply valve on.
2. Brush a half and half solution of liquid soap and water onto all joints and connections of the regulator,hose, manifolds
and valves.
3. Bubbles will indicate a gas leak. Either tighten the loose joint or replace the part with one recommended by the dealer.
4. If the leak cannot be stopped, shut off the gas supply,disconnect it and have the barbecue inspected by your gas
supplier or dealer.Do not use the appliance until the leak has been corrected.
5. Turn offgas supply.
GAS HOOK-UP INSTRUCTIONS
CYLINDER CONNECTION: Ensure that the gas regulator hose is kink free. Remove the cap or plug from the cylinder fuel
valve. Insert the black QCC1 regulator nipple onto the QCC1 fuel valve. Hand tighten clockwise.

Do not use tools. Leak test all

joints prior to using the barbecue.

Aleak test must be performed annually, and each time a cylinder is hooked up, or if a part of the
gas system is replaced.
PROPANECYLINDER INSTALLATION: Set cylinder into hole in bottom shelf.
IMPORTANT: The regulator must be attached so that no part of the hose touches the underside of the grill or drippan.
A fire will result if these directions are ignored.
NATURALGAS HOOK-UP: This natural gas grill is supplied with a 10ft supply hose (complete with a quick disconnect) designed
for natural gas and certified for outdoor use. Thegas grill is designed to operate at an inlet pressure of 7 inches water column. Piping
and valves upstream of the quick disconnect are not supplied.
The quick disconnect must not be installedin an upward direction and a readily accessible manual shut-off valve must be installed
upstream of, and as close to, the quick disconnect as is feasible. Theflared end of the hose must be connected to the unit as
illustrated in the

Natural Gas HoseAttachment

diagram. These connections must be made by a licensed gas installer. Leak test all
joints prior to using the gas grill.
MODEL SS450RSB: Connect the 20" hose from the manifold, to the side burner as illustrated in the

Natural Gas Hose Attach-

ment

diagram. Connectthe supply hose to the flare connection which faces down from the side burner. Tighten all connections
using two wrenches. (

Do not use thread sealer/pipe dope.)

LEAK TESTING INSTRUCTIONS