©NationalInstruments Corp. 7 FP-PS-4Operating Instructions
Ensurethat all the wiring is installed according to local codes and
regulationsby qualified electrical personnel. Follow these steps to
connectthe FP-PS-4 to your FieldPoint system.
1. Usea 16 to 26 AWG stranded wire to connect the FP-PS-4 to
yourFieldPoint network module or I/O module. Connect the
positivewire to the V terminal and the negative wire to the
Cterminal of the FP-PS-4.
2. Connectthe other ends of the wires to the V and C terminals of
theFieldPoint network module or I/O module.
3. Ensurethat the plug-in AC input terminal connector is plugged
intothe input port on the FP-PS-4.
Note Becareful to install the correct conductor in t he
appropriateterminal. The color of the conductorwires
variesdepending on North American versus international
standardsas described in Figure 7. The wires are drawn
toscale according to the 7 mm(0.275 in.) strip length
requirement.
Figure7. Conductor Wire Color Standards for the Plug-in AC Input
TerminalConnector
4. Connectthe black or brown conductor into the line terminal
labeledL.
5. Connectthe white or blue conductor into the neutral terminal
labeledN.
1 Line wire (black by North American standards; brown by international
standards)
2 Neutral wire (white by North American standards; blue by international
standards)
3 Ground wire (green by North American standards; green/yellow by
internationalstandards)
4 Plug-in AC input terminal connector
1
2
3
LN4