© National Instruments Corporation 19 NI cDAQ-9172 User Guide and Specifications
module in the cDAQ chassis, the maximum Sample Clock rate can run 
faster than the maximum rate for the module. When operating at a rate 
faster than these slow rate modules can support, the slow rate module 
returns the same point repeatedly, until a new conversion completes. The 
first point is acquired when the task is committed. The second point is 
acquired after the start trigger.
Figure 11.  Sample Clock Timing Example
For example, if running an AI task at 1 kHz using a module with a 
maximum rate of 10 Hz, the slow module returns 100 samples of the first 
point, followed by 100 samples of the second point, etc. Other modules in 
the task will return 1,000 new data points per second, which is normal. 
When performing a single-point acquisition, no points are repeated.
Refer to the KnowledgeBase document, C Series Modules Supported in the 
NI cDAQ-9172, for more information. To access this KnowledgeBase, 
go to ni.com/info and enter the info code rdcdaq.
Getting Started with AI Applications in SoftwareYou can use the NI cDAQ-9172 chassis in the following analog input 
applications:
• Single-Point
•Finite
• Continuous
ai/StartTrigger 
Data from
A/D Conversion
(Slow Module)
ai/SampleClock 
Data Returned
to AI Task
1st A/D Conversion  2nd A/D Conversion  3rd A/D Conversion 
A  B C 
A A  A B B  B C