National Instruments NI UES-3880 manual Specifications, Technology, Interface, Power

Models: NI UES-3880

1 14
Download 14 pages 39.15 Kb
Page 12
Image 12

Specifications

Technology

Standards

Forward and Filtering

Rate

Packet Buffer Memory

Processing Type

Address Table Size

Latency

Interface

RJ45 Ports

LED Indicators

DIP Switch

Alarm Contact

Power

Input Voltage

Input Current @ 24VDC Connection

Overload Current Protection Reverse Polarity Protection

Mechanical Casing Dimensions Weight Installation Environmental Operating Temperature Storage Temperature Ambient Relative Humidity

Regulatory Approvals

Safety

Hazardous Location

EMI

EMS

Operating Shock Operating Vibration

IEEE802.3, 802.3u, 802.3x 148810 pps

256 KB

Store and Forward, with IEEE802.3x full duplex, back pressure flow control

1K uni-cast addresses Less than 5 μs

10/100BaseT(X) auto negotiation speed, F/H duplex mode, and auto MDI/MDI-X connection

Power, Fault, 10M, 100M Port break alarm mask

One relay output with current carrying capacity of 1A @ 24 VDC

12 to 48 VDC, redundant inputs

0.25 A

Removable “6-pin” Terminal Block

1.1A

Present

IP30 protection, metal case

53.6⋅ 135 ⋅ 105 mm (W ⋅ H ⋅ D)

0.63kg

DIN-rail, Wall Mounting

-40 to 75ºC (-40 to 167ºF) -40 to 85ºC (-40 to 185ºF)

5 to 95% (non-condensing)

UL60950-1, CSA C22.2 No. 60950-1, EN60950-1,

TUV

UL/cUL Class I, Division 2, Groups A, B, C, and D FCC Part 15, CISPR (EN55022) class A EN61000-4-2 (ESD), Level 3

EN61000-4-3 (RS), Level 3

EN61000-4-4 (EFT), Level 3

EN61000-4-5 (Surge), Level 3 EN61000-4-6 (CS), Level 3 15g, half-sine, 11 ms pulse 10 Hz to 150 Hz, 1 grms

— 11 —