Chapter 1 Introduction and Quick Start
©
National Instruments Corporation 1-13 VXI/VME-PCI802 2 for Sola ris
VXI/VME-MXI-2This section summarizes the hardware and software defa ult settings for
the VXI-MXI-2 and VME-MXI-2.
User Window Size 64 KB
Driver Window Size 32 KB
Expansion ROM Enabled
Table 1-5. VXI-MXI-2 Hardware Default Settings
Hardware Component Default Setting
Logical Address (U43) 1
VXIbus Slot 0/Non-Slot 0 (W2) Automatic detection
VXIbus Local Bus (S8, S9) Both OFF: Single VXI-MXI-2
VXIbus CLK10 Routing (W3) From onboard oscillator
External Trigger Termination (S2) OFF: Unterminated
SMB CLK10 Direction (S3) OUT: Drive CLK10 signal
SMB CLK10 Termination (S4) Ignored; effective only when S3
is set to IN.
Polarity of External SMB CLK10
(S5) Inverted
MXIbus CLK10 Signal (S7) Receive CLK10 from MXIbus
MXIbus Termination
(U35 switches 1 and 2) Automatic MXIbus termination:
switch 2 set to NO; switch 1
ignored.
Table 1-4. PCI-MXI-2 Bus Configuration Editor Default Settings (Continued)
Editor Field Default Setting