![PROCEDURE 3ÐCHECKING GAS PIPING](/images/new-backgrounds/46355/4635521x1.webp)
4.Install a sediment trap upstream of gas controls.
5.Use 2 pipe wrenches when making connection to gas valve to keep it from turning.
6.Install a manual shutoff valve in vertical pipe about 5 ft above floor.
7.Tighten all joints securely.
8.Propane gas connections should only be made be a licensed propane installer.
9.
10.Propane gas piping should be checked be propane installer.
PROCEDURE 3ÐCHECKING GAS PIPING
Upon completion of piping, check immediately for gas leaks. Open the manual shutoff valve. Test for leaks by applying soap suds (or a liquid detergent) to each joint. Bubbles forming indicate a leak. CORRECT EVEN THE SMALLEST LEAK AT ONCE.
WARNING: Never use a match or open flame to test for leaks. Use a
ELECTRICAL WIRING
All electrical work must conform to local codes as well as the National Electrical Code (NEC)
See Fig. 7 for unit wiring diagram.
PROCEDURE 1ÐELECTRIC POWER SUPPLY
WARNING: Turn off electric power at fuse box before making any line voltage connections. Follow local electric codes. Failure to follow this warning could result in electrical shock, personal injury, or death.
CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.
Run a separate
The boiler, when installed, must be electrically grounded in accordance with the requirements of the authority having jurisdiction, or in the absence of such requirements, with the NEC. Run a 14 gage or heavier copper wire from boiler to a grounded connection in service panel or a properly driven and electrically grounded ground rod.
PROCEDURE 2ÐINSTALLING THERMOSTAT
Thermostat location has an important effect on the operation of boiler system. BE SURE TO FOLLOW INSTRUCTIONS INCLUDED WITH THERMOSTAT.
Locate thermostat about 5 ft above floor on an inside wall. It may be mounted directly on wall or on a vertically mounted outlet box. It should be sensing average room temperature so avoid the following:
DEAD SPOTS:
Behind doors
Corners and alcoves
HOT SPOTS:
Concealed pipes
Fireplace
TV sets
Radios
Lamps
Direct sunlight
Kitchens
COLD SPOTS:
Concealed pipes or ducts
StairwellsÐdrafts
DoorsÐdrafts
Unheated rooms on other side of wall
Set heat anticipator at 0.2 amps. The
SEQUENCE OF OPERATION
1.Thermostat calls for heat, powering 1K relay coil and closing contacts 1K1 and 1K2.
2.Circulator pump is powered through terminals C1 and C2.
3.Induced draft blower and AT 140C transformer primary are powered through terminals B1 and B2.
Ð11Ð