ControlSync

1.Connect the master monitor with a sub monitor via a ControlSync cable (ø 2.5) into ControlSync IN/OUT.

2.Follow the steps of DATA COPY. When the setting of the master monitor is adjusted, it will be copied and sent to the connected sub monitor(s) automatically.

3.Up to 5 sub monitors can be daisy-chained via ControlSync.

NOTE: Connect the master monitor via ControlSync OUT connector.

 

 

ControlSync icon

 

 

The ControlSync icon will appear on the upper left of the OSD menu in the sub monitor.

Do not connect IN-IN or OUT-OUT.

 

 

 

Do not make “loop” connection.

 

 

 

Once the monitors are connected, turn the master monitor’s power button off and on

to check if ControlSync operates correctly.

 

 

 

Master Monitor

 

 

 

Sub Monitor 1

Sub Monitor 2

English

OUT (Black)

IN OUT

IN OUT

 

Up to 5 sub monitors

 

 

 

(Black)

(Gray)

 

 

Next monitor

 

ControlSync cable

(Black)

(Gray)

 

IN (Gray)

 

 

ControlSync cable

The following settings can be controlled by ControlSync:

ECO TOOLS

BRIGHTNESS*

Yes

 

CONTRAST

No

 

ECO MODE

Yes

 

AUTO BRIGHTNESS

Yes

 

BLACK LEVEL

No

 

OFF MODE SETTING

Yes

 

OFF MODE SENSOR SETTING

Yes

 

OFF MODE START TIME

Yes

 

HUMAN SENSING

Yes

 

HUMAN SENSOR SETTING

Yes

 

HUMAN SENSOR START TIME

Yes

 

DV MODE

Yes

SCREEN

AUTO ADJUST

No

 

AUTO CONTRAST

No

 

LEFT/RIGHT

No

 

DOWN/UP

No

 

H.SIZE

No

 

FINE

No

 

INPUT RESOLUTION

No

COLOR

Color preset

Yes

 

R, G, B, color gain

No

TOOLS

VOLUME

Yes

 

SOUND INPUT

No

 

VIDEO LEVEL

No

Other settings:

Power Control (DC switch)

Ambient Sensor

Human Sensor Result

Audio Mute

TOOLS (continuation)

OVER SCAN

No

 

VIDEO DETECT

No

 

EXPANSION MODE

Yes

 

RESPONSE IMPROVE

No

 

OFF TIMER

Yes

 

POWER SAVE TIMER

No

 

LED BRIGHTNESS

Yes

 

DDC/CI

Yes

 

FACTORY PRESET

No

MENU TOOLS

LANGUAGE

Yes

 

OSD TURN OFF

Yes

 

OSD LOCK OUT

Yes

 

HOT KEY

Yes

 

SIGNAL INFORMATION

Yes

 

SENSOR INFORMATION

Yes

 

KEY GUIDE

Yes

 

CUSTOMIZE SETTING

No

ECO INFORMATION

CARBON SAVINGS

No

 

CARBON USAGE

No

 

COST SAVINGS

No

 

CARBON CONVERT SETTING

Yes

 

CURRENCY SETTING

Yes

 

CURRENCY CONVERT

Yes

 

SETTING

 

 

NOTE: Only the master monitor’s human sensor and ambient sensor are active. Please do not cover these sensors. Turn the monitor’s power off before connecting/disconnecting the ControlSync cable.

Do not use the ControlSync connectors for any purpose other than specifi ed.

*This value is not a directly adjusted output value. This is adjusted relatively.

English-23

Page 25
Image 25
NEC EA244WMI-BK user manual ControlSync, English-23