NEC LCD2090UXI user manual English-19

Models: LCD2090UXI

1 29
Download 29 pages 606 b
Page 21
Image 21
English-19

Tag3

Auto Adjust

Automatically adjusts the Image Position and H.Size settings and Fine settings.

 

(Analog input only)

Press “SELECT” to activate Auto Adjustment.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Signal Adjust

Determines when the auto adjustment is activated automatically.

 

 

 

(Analog input only)

The choices are “SIMPLE” and “FULL”. Press “Left” or “Right” to select.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H-size, Fine, H/V Position

 

Contrast

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SIMPLE

O

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FULL

O

 

O

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

O: Automatic Adjustment X: No Automatic Adjustment

 

 

 

 

 

 

NOTE: Automatic Adjustment does not work at resolutions less than 800x600 resolution.

 

 

 

 

 

 

 

 

 

 

 

 

Auto Adjust Level

Determines the automatic adjustment level for Auto Adjust. The choices are “SIMPLE”,

 

(Analog input only)

“FULL” and “DETAIL”. Press “Left” or “Right” to select. Refer to the below table.

 

 

 

 

Size, Fine, Position

 

Contrast

 

Black Level,

 

Time

 

 

 

 

 

 

 

 

 

 

 

Long cable capability**

 

 

 

 

 

 

SIMPLE

O

 

 

X

 

X

 

1 second

 

 

 

 

FULL

O

 

 

O

 

X

 

1.5 seconds

 

 

 

 

DETAIL*

O

 

 

O

 

O

 

5 seconds

 

 

 

O: Automatic Adjustment X: No Automatic Adjustment

 

 

 

 

 

 

* “DETAIL” activates automatic long cable (skew, peaking) adjustment.

 

 

 

 

** Black level, RGB sharpness, RGB delay and RGB position are adjusted using “Long cable software”

 

 

which is included in the attached CD-ROM.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A-NTAA SW

The Advanced No Touch Auto Adjust function is able to recognize new signals even when

 

(Analog input only)

neither the resolution nor the refresh rate has changed. If several PCs are connected to

 

 

the monitor, and each transmit very similar (or even the same) signals in terms of

 

 

resolution and refresh rates, the monitor recognizes that there is a new signal and

 

 

automatically optimizes the picture without the need for any action on the part of the user.

 

 

OFF: A-NTAA is disabled.

 

 

 

 

 

 

 

 

 

 

ON: If a change in signal is detected A-NTAA will adjust the monitor to the optimal settings

 

 

for the new signal. If no change in the signal is detected then A-NTAA does not activate.

 

 

The screen will be blank while the monitor optimizes the signal.

 

 

 

 

OPTION: Functions the same as ON, except that the screen does not go blank when the

 

 

monitor makes adjustments for changes in signal, allowing the monitor to display the new

 

 

signal faster. When using an external switching device to connect 2 or more PCs to the

 

 

monitor, using the ON or OPTION settings is suitable.

 

 

 

 

 

 

 

 

 

 

 

 

 

Tag4

H. Position

Controls Horizontal Image Position within the display area of the LCD.

 

 

Press “Left” or “Right” to adjust.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V. Position

Controls Vertical Image Position within the display area of the LCD.

 

 

Press “Left” or “Right” to adjust.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H. Size

Adjusts the horizontal size of the screen.

 

 

 

 

 

(Analog input only)

If the “AUTO Adjust function” do not give you a satisfactory picture setting, a further

 

 

tuning can be performed using the “H.Size (V.Size)” function (dot clock). For this a Moiré

 

 

test pattern could be used. This function may alter the width of the picture. Use left/Right

 

 

Menu to center the image on the screen. If the H.Size (V.Size) is wrongly calibrated, the

 

 

result would look like on the left drawing. The image should be homogeneous.

 

 

 

 

 

 

 

 

 

 

 

 

Fine

Improve focus, clarity and image stability by increasing or decreasing this setting.

 

(Analog input only)

If the “Auto Adjust function” and the “H.Size” function do not give you a satisfactory

 

 

picture setting, a fine tuning can be performed using the “Fine” function. For this a Moiré

 

 

test pattern could be used. If the Fine value is wrongly calibrated, the result would look

 

 

like on the left drawing. The image should be homogeneous.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Auto Fine

This function automatically and periodically adjusts the “FINE” setting for change in signal

 

(Analog input only)

condition. This function adjusts approximately every 33 minutes.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H. Resolution

Adjusts the horizontal size by increasing or decreasing the setting.

 

 

Press “Right” button to expand the width of the image on the screen.

 

 

Press “Left” button to narrow the width of the image on the screen.

 

 

 

 

 

 

 

 

 

 

 

 

 

V. Resolution

Adjusts the vertical size by increasing or decreasing the setting.

 

 

 

 

Press “Right” button to expand the height of the image on the screen.

 

 

Press “Left” button to narrow the height of the image on the screen.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Expansion

Sets the zoom method.

 

 

 

 

 

 

 

 

 

 

FULL: The image is expanded to 1600 x 1200, regardless of the resolution.

 

 

ASPECT: The image is expanded without changing the aspect ratio.

 

 

OFF: The image is not expanded.

 

 

 

 

 

 

CUSTOM: When CUSTOM is selected as the Expansion mode, it becomes possible to

 

 

adjust the H. ZOOM., V. ZOOM, and ZOOM POS.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

English

English-19

Page 21
Image 21
NEC LCD2090UXI user manual English-19