Manuals
/
Brands
/
Communications
/
IP Phone
/
NEC
/
Communications
/
IP Phone
NEC
ND-70919 system manual
1
1
211
211
Download
211 pages, 2.35 Mb
ND-70919 (E)
ISSUE 1
STOCK # 151988
ISDN System Manual
®
FEBRUARY, 2000
NEC America, Inc.
Contents
Main
Page
Page
Page
ISDN System Manual
NEAX2000 IVS ISDN System Manual
TABLE OF CONTENTS
TABLE OF CONTENTS
LIST OF FIGURES
LIST OF TABLES
Page
INTRODUCTION
PURPOSE
OUTLINE OF THIS MANUAL
REFERENCE MANUALS
Page
SYSTEM OUTLINE
System Outline of ISDN-PRI
Figure 1-1 System Outline of ISDN-PRI
System Outline of ISDN-BRI
Figure 1-2 System Outline of ISDN-BRI
NOTE: NT1 equipment must be installed in the premise.
System Outline of ISDN-VPN
Figure 1-3 Example of ISDN-VPN (1 of 2)
Figure 1-3 Example of ISDN-VPN (2 of 2)
When an opposite office cannot interface with the ISDN network
Page 8
System Outline of ISDN Terminal
Figure 1-4 System Outline of ISDN Terminal (for ISDN-PRI)
Figure 1-5 System Outline of ISDN Terminal (for ISDN-BRI)
DTI
DCH
PRT
BRT
PLO
Figure 1-6 Clock Supply Rout e
Page
Page 14
Outline of Event Based CCIS
OUTLINE OF EVENT BASED CCIS
Figure 1-7 System Outline of Event Based CCIS
Common Channel and Voice Channel Link Control
Figure 1-8 Release Timing of Virtual Tie Line and CCIS Link
Figure 1-9 Virtual Trunk
Event Based CCIS Feature List
Table 1-1 Event Based CCIS Feature List
Page
Table 1-1 Event Based CCIS Feature List (Continued)
Event Based CCIS Service Conditions
CARD NAME AND FUNCTION
Table 1-2 ISDN Card Name and Function CARD NAME FUNCTIONAL NAME FUNCTION
SYSTEM CAPACITY
System Capacity for ISDN-PRI
Table 1-3 System Capacity for ISDN-PRI DESCRIPTION CAPACITY 24DTI 24PRT 30DTI
System Capacity for ISDN-BRI
Table 1-4 System Capacity for ISDN-BRI DESCRIPTION CAPACITY
Page 24
System Conditions
SYSTEM CONDITIONS
Time Slot Assignment Condition
Figure 1-10 Accommodation of DTI/DCH/ICH/BRT/PRT into TDSW
Time Slot Allocation for DTI/PRT/DCH Card
Figure 1-11 Time Slot Allocation for DTI
Page 26
System Conditions
Line Distance Between PBX and NT1/ISDN Terminal
NOTE 1: The line distance marked by * shows the value when the 0.5
Figure 1-12 Line Distance Between PBX and NT1/ISDN Terminal
twisted-pair cable is used. NOTE 2: The line distance marked by ** shows the value when the 0.65
twisted-pair cable is used.
DTI SPECIFICATIONS
Transmission Characteristics
Table 1-5 Transmission Characteristics CHARACTERISTICS 24-CHANNEL 30-CHANNEL
Table 1-5 Transmission Characteristics (Continued) CHARACTERISTICS 24-CHANNEL 30-CHANNEL
Frame Configuration of 24DTI
Figure 1-13 DTI Frame Configuration (12-Multi Frame)
Page
Figure 1-14 DTI Frame Configuration (24-Multi Frame)
Table 1-7 24-Multi Frame Bit Assignment FRAME No.
S BIT FRAME SYNCHRONIZATION 4 Kbps DATA LINK CRC
Frame Configuration of 30DTI
Figure 1-15 Frame Configuration of 30DTI
Table 1-8 Time Slot Assignment of 30DTI TIME SLOT No. EVEN No. FRAME ODD No. FRAME
Page
PRECAUTIONS
Static Electricity Guard
Figure 2-1 Static Electricity Guard (1 of 2)
Figure 2-1 Static Electricity Guard (2 of 2)
ATT EN TI ON
CAUTION
REQUIRED EQUIPMENT
ISDN-PRI Required Equipment
ISDN-BRI Required Equipment
Table 2-1 ISDN-PRI Required Equipment EQUIPMENT DESCRIPTION QUANTITY REMARKS
Table 2-2 ISDN-BRI Required Equipment EQUIPMENT DESCRIPTION QUANTITY REMARKS
ISDN Terminal Required Equipment
Event Based CCIS Required Equipment
INSTALLATION PROCEDURE FOR ISDN-PRI
Figure 2-2 Installation Procedure for ISDN-PRI
Mounting DTI and DCH Card/PRT Card
Mounting CONN Card
DTI/PRT Cable Connection via MDF
Figure 2-3 DTI/PRT Cable Connection via MDF
Figure 2-4 Location of AP Slots and LTC Connectors for DTI/PRT
Page 46
Installation Procedure for ISDN-PRI
Figure 2-5 Example of MDF Cross Connection for DTI/PRT
Cable Connection via CONN Card
Figure 2-6 Cable Connection via the CONN Card
Page 48
Installation Procedure for ISDN-PRI
Figure 2-7 Example of Coaxial Cable Connection
INSTALLATION PROCEDURE FOR ISDN-BRI
Figure 2-8 Installation Procedure for ISDN-BRI
Mounting BRT Card
BRT Cable Connection via MDF
Figure 2-9 BRT Cable Connection via MDF
Page 52
Figure 2-10 Location of AP Slots and LTC Connectors for BRT
9
8
7
6
Figure 2-11 Example of MDF Cross Connection for BRT (1 of 2)
Page 54
Figure 2-11 Example of MDF Cross Connection for BRT (2 of 2)
INSTALLATION PROCEDURE FOR ISDN TERMINAL
Install the equipment for the ISDN Terminal according to the procedure shown in Figure 2-12.
Figure 2-12 Installation Procedure for ISDN Terminal
Mounting ICH Card
Mounting ILC Card
Page 58
ILC Cable Connection via MDF
See Page 26.
Figure 2-13 ILC Cable Connection via MDF
Figure 2-14 Location of LT Slots and LTC Connectors for ILC
NOTE: Be sure to mount an ILC card on the LTC connector separated from analog line /trunk cards.
Page 60
Figure 2-15 Example of MDF Cross Connection for ILC
Installation Procedure for Event Based CCIS
INSTALLATION PROCEDURE FOR EVENT BASED CCIS
Figure 2-16 Installation Procedure for Event Based CCIS
Mounting CCH Card
Page
HOW TO READ THIS CHAPTER
ISDN-PRI PROGRAMMING
Digital Trunk Data Assignment
Page
Page
Page
Page
For originating calls to the ISDN, do the following programming:
When providing Tandem Connection (ODT/DTI to ISDN, ISDN to ODT/DTI), do the following
When providing Tandem Connection (ISDN to CCIS, CCIS to ISDN), do the following
D Channel Handler Assignment
Page
ISDN-BRI PROGRAMMING
BRT Assignment
Page
Page
Page
For originating calls to the ISDN network, do the following pr ogramming:
Page
When providing Tandem Connection (ISDN to CCIS, CCIS to ISDN), do the following
Specify whether the Calling Party Number (CPN) sent from ISDN is sent to the CCIS network.
ISDN FEATURE PROGRAMMING
DID Addressing
Page
MEGACOM Access
[North America Only]
SID to Network-Present/ CPN to Network-Present
When ISDN (BRI) Terminals are used:
Page
When Dial-In service is not provided:
NOTE 1
NOTE 2
Subaddress-Present
Trunk Provisioning Service Selection
ISDN PRI Call By Call Service Selection
Page
Page
Page
Page
Page
Advice of Charge (AOC)
Centrex SHF Over ISDN
ISDN-VPN PROGRAMMING
Page
ISDN TERMINAL DATA PROGRAMMING
Page
Page
Point-to-Point Connection
Point-to-Multipoint Connection
Page
Individual Terminal Call
Page
Page
Page 110
ISDN Terminal Data Programming
Do the programming of Point-to-Multipoint Connection. See Page 105.
Group Call
Page
Page
Page
Event Based CCIS Programming
EVENT BASED CCIS PROGRAMMING
PBX B
PBX A
Programming Summary
Figure 3-1 Outline of BRI to BRI Connections
Figure 3-2 Event Based CCIS Programming Summary
Numbering Plan Programming
BRI Trunk Programming
Page
Page
Page
Home-Side Trunk Programming
Page
Mate-Side Trunk Programming
Page
Page
Figure 3-3 shows an example of the programming for verification of connection.
Figure 3-3 Verification of Connection
Page
Page
Page
Incoming Termination for Event Based CCIS Calls
Access Code/Terminating Number Assignment for Outgoing Event Based Calls
Release Timer for Virtual Tie Lines (Home-Side and Mate-Side Trunks)
CCH Data Assignment
Tandem Connection Programming
When providing Tandem Connection (ISDN to CCIS/CCIS to ISDN), do the following
Closed Numbering Plan Programming
Page
HOW TO READ THIS CHAPTER
MOUNTING LOCATION OF CIRCUIT CARD
Figure 4-1 Mounting Location of Circuit Card
LIST OF REQUIRED CIRCUIT CARDS
Table 4-1 List of Required Circuit Card
NAME)
PAGE
PN-CP14 (MP)
PN-CP14 (MP)
CONN: To CONNR connector on PZ-M537 (EXPMEM)
CAUTION
Page
SWITCH NAME SWITCH NUMBER SETTING
SW4-3 SW4-4 FUNCTION
Page
Page 146
PN-BRTA (BRT)
PN-BRTA (BRT)
Page
SWITCH NAME SWITCH NUMBER SETTING
AP No. SW No.
Page
Page
PN-2BRTC (BRT)
PN-2BRTC (BRT)
Page
Page
Page
Page
Page 156
PN-24DTA-C (DTI)
PN-24DTA-C (DTI)
Page
Page
Page
Page
Page
Page 162
PN-30DTC-A (DTI)
PN-30DTC-A (DTI)
Page
Page
Page
Page
Page
Page 168
PN-24PRTA (PRT)
PN-24PRTA (PRT)
Page
Page
Page
Page
Page
PN-SC00 (CCH)
Page
Page
PN-SC01 (DCH)
Page
Page
PN-SC03 (ICH)
SWITCH NAME SWITCH NUMBER SETTING
AP No. SW No.
Page 182
PZ-M542 (CONN)
PZ-M542 (CONN)
This card has no lamps.
Page
Page 184
PZ-M557 (CONN)
PZ-M557 (CONN)
This card has no lamps.
Page
Page 186
PN-2ILCA (ILC)
PN-2ILCA (ILC)
Page
Page
Page
INTEROFFICE TRANSMISSION LINE TEST
Table 5-1 Alarm Indications on 24DTI
Table 5-2 Alarm Indications on 30DTI
Table 5-3 Alarm Indications on 24PRT
Table 5-4 Alarm Indications on BRT
PLO OPERATION TEST
Clock Signal Generation Test
Clock Signal Synchronization Test
Page
Interoffice Synchronization Test
Source Office Mode Test