NEAX2000 IVS2 ISDN System Manual
Page 154 ND-70919 (E), Issue 1.0
CHAPTER 4 CIRCUIT CARD INFORMATION
PN-2BRTC (BRT)
The figure in the SWITCH NAME column and the position in in the SETTING POSITION
column indicate the standard setting of the switch. When the switch is not set as shown by the
figure and , the setting of the switch varie s with the system concerned.
NOTE 1: Set the groove on the switch to the desired position.
NOTE 2: When the power is on, flip the MB switch to ON (UP position) before plugging/
unplugging the circuit card.
SW11 (DIP SW)
1For normal operation
OFF Not used
2
NOTE 3
NOTE 4
ON Output clock signals according to
the switch setting of SW11-3
OFF Do not output clock signals.
3
NOTE 3
NOTE 4
ON Output clock signals to PLO0 of MP
OFF Output clock signals to PLO1 of MP
4ON AP No. 04-15
OFF AP No. 20-31
(Continued)
SWITCH NAME SWITCH
NUMBER SETTING
POSITION FUNCTION CHECK
1234
ON
ON