CHAPTER 4 CIRCUIT CARD INFORMATION
PN-24DTA-C (DTI)
NEAX2000 IVS2 ISDN System Manual
ND-70919 (E), Issue 1.0 Page 159
SW0
(Piano Key SW) 1
NOTE 3
NOTE 4
ON Source clock signal from network is
sent to the PLO0 input on MP card.
OFF
Source clock signal from network is
not sent to the PLO0 input on MP
card.
2
NOTE 3
NOTE 4
ON Source clock signal from network is
sent to the PLO1 input on MP card.
OFF
Source clock signal from network is
not sent to the PLO1 input on MP
card.
3ON Remote loop-back
For normal operation
4ON Local loop-back (AIS send)
For normal operation
5Set equalizer according to the cable
length between the PBX and the
MDF.
OFF
6OFF
7OFF
8 Not used
(Continued)
SWITCH NAME SWITCH
NUMBER SETTING
POSITION FUNCTION CHECK
OFF
ON
5
6
7
8
1
2
3
4
OFF
OFF
ON
OFF 80-120 m (262.5-394 ft.)
SW0-5 SW0-6 SW0-7
CABLE LENGTH
ON ON 0-40 m (0-131.2 ft.)
40-80 m (131.2-262.5 ft.)
120-160 m (394-525 ft.)
160-200 m (525-656 ft.)
Signal is not sent
ONON ON
ONON OFF OFFON OFF ONOFF ON OFFOFF OFF
ON
ON
OFF