![](/images/new-backgrounds/1109556/10955645x1.webp)
NTI RACKMUX KVM Drawer with NODEMUX Switch
RS - reset unit(s) to default
FORMAT: RS AA<CR>
RS = "reset unit" command followed by at least one space
| AA = unit address; if 00, all units on the bus will be reset and no response will be |
| returned |
RESPONSE: | *<CR> if command received and executed OK |
|
?<CR> if syntax or transmission error occurred
Note: The RS command does not change the switch configuration, it changes
CS - change single USER channel
FORMAT: CS AA,XX,YY<CR>
CS = "change single output" command followed by at least one space
AA = unit address
XX= input/CPU to connect
YY= output/USER to change
RESPONSE: | *<CR> (command received and executed OK) |
?<CR> (syntax or transmission error occurred)
CA - change all output channels
FORMAT: | CA AA,XX<CR> |
| CA = "change all outputs" command followed by at least one space |
| AA = unit address |
| XX = input /CPU to connect to all outputs/USERS |
RESPONSE: | *<CR> (command received and executed OK) |
| ?<CR> (syntax or transmission error occurred) |
FYI: In this NODEMUX switch, this command will have the same effect as the CS command above.
RO - read single USER channel
FORMAT: | RO AA,YY<CR> |
| RO = "read output" command followed by at least one space |
| AA = unit address |
| YY = output/USER to read |
RESPONSE: | *<CR> (command received and executed OK) |
| XX<CR> (XX = input/CPU connected) |
| |
| ?<CR> (syntax or transmission error occurred) |
RU - read unit size | |
FORMAT: | RU AA<CR> |
| RU = "read unit size" command followed by at least one space |
| AA = unit address |
RESPONSE: | *<CR> (command received and executed OK) |
| XX,YY<CR> (XX = # of CPU’s, YY = # of USERS) |
| |
| ?<CR> (syntax or transmission error occurred) |
19