POSSIBLE TOOLS NEEDED FOR INSTALLATION

If you decide to install your own stove, there are several hand tools you may need to do the job. If you do not already have them, they are readily available at most hardware stores.

Caulking gun

Large adjustable wrench (may not be needed) Drop cloths or newspapers

Vacuum cleaner or whisk broom Flashlight

1 tube of RTV silicone, Code 103 or 106, or high temperature rubber cement rated between 450o F- 600o F

7/32" drill bit and drill Socket/Ratchet Set

INSTALLATION PREPARATION

Fireplace:

1.Locate furniture and other materials away from front of fireplace to allow free access to fireplace.

2.Cover hearth and adjacent floor areas with a drop cloths to protect from soiling or marring surface.

3.Remove existing fireplace damper plate.

4.Thoroughly clean fireplace of ashes and soot.

5.Check chimney and smoke chamber for excessive buildup of creosote or soot. Also, check for obstructions, such as bird’s nests. If chimney is excessively dirty, clean it or have someone clean it professionally BEFORE installing or using room heater.

6.If fireplace has an ash dump or outside air provision, these must be sealed off with metal or tightly packed non-combustible insulation to prevent cold air from entering fireplace chamber.

MASONRY INSERT INSTALLATION

INSTALLATION OPTIONS

This unit (appliance) may be installed into an all masonry fireplace, built in accordance with Uniform Building Code and National Fire Protection Association (NFPA 211).

NOTE: Check with local building officials for any permits required for installation of this unit and notify your insurance company before proceeding with installation

In cases such as improperly drawing fireplaces, oversize flue liners or to meet codes in certain areas it is recommended that one of the flowing procedures be followed:

A. A Chimney Connector be installed from appliance flue exit through damper, plus a air-tight face seal. See option (A) page 8.

B. A listed Direct Connect be installed from appliance flue exit through damper, into first section of flue liner with air-tight seal. See option (B) page 8.

C. A Positive Connect be installed from appliance flue exit continuing up through entire chimney and exiting at top of chimney. See option (C) page 8.

Page 7

Page 9
Image 9
New Buck Corporation 81 installation instructions Possible Tools Needed for Installation, Installation Options

81 specifications

New Buck Corporation 81 represents a significant advancement in industrial technology, specifically designed to meet the evolving demands of various markets. Renowned for its robustness and reliability, the Corporation 81 model has become a staple in manufacturing environments where precision and durability are paramount.

One of the main features of the New Buck Corporation 81 is its state-of-the-art manufacturing capability. The system integrates advanced automated processes that enhance efficiency while minimizing human error. With a throughput capacity that surpasses previous models, the Corporation 81 can handle large volumes of production without sacrificing quality. This is achieved through its high-speed components and optimized workflow design.

Incorporating cutting-edge technology, the Corporation 81 leverages real-time data analytics to provide operators with valuable insights into performance metrics. This data-driven approach allows for continuous monitoring and immediate adjustments, ensuring that production standards remain high. Additionally, the machine is equipped with predictive maintenance features that alert operators to potential issues before they escalate, thereby reducing downtime.

Another notable characteristic of the New Buck Corporation 81 is its versatility. The system is designed to accommodate a wide range of materials and product types, making it ideal for diverse manufacturing applications. Whether it is fabricating complex components or producing simpler items, the Corporation 81 adapts seamlessly to different tasks.

The user interface of the Corporation 81 has also been refined for enhanced operability. An intuitive touchscreen display provides a straightforward way to navigate through settings and monitor production. This user-friendly aspect minimizes the training time required for new operators, making it easier for companies to employ this technology effectively.

Moreover, the New Buck Corporation 81 is engineered with sustainability in mind. Its energy-efficient designs reduce power consumption, aligning with modern environmental standards. By incorporating eco-friendly practices, the Corporation 81 contributes to reducing the overall carbon footprint of manufacturing processes.

In conclusion, New Buck Corporation 81 stands out in the industrial landscape with its combination of efficiency, adaptability, and intelligent technologies. Businesses looking to enhance their production capabilities will find in the Corporation 81 a reliable partner that meets contemporary demands while paving the way for future innovations. With its impressive feature set, this model is poised to redefine standards in manufacturing excellence.