New Buck Corporation FP-BR-10-ZC manual Depleted gas supply

Models: FP-BR-10-ZC

1 38
Download 38 pages 40.08 Kb
Page 31
Image 31
Depleted gas supply

 

 

 

5.

Depleted gas supply

 

5.

Contact local propane

 

 

 

 

 

 

 

 

 

 

 

gas company

 

 

 

6.

ODS/Pilot is clogged

 

6.

Clean ODS/Pilot or

 

 

 

 

 

 

 

 

 

 

 

replace ODS/Pilot

 

 

 

 

 

 

 

 

 

 

 

assembly

 

 

 

7.

Gas regulator setting is not

7.

Replace gas regulator

 

 

 

 

correct

 

 

 

 

 

 

 

 

 

 

 

 

 

3. ODS/Pilot

lights

but

1.

Control knob is not fully

1.

Press control knob

flame goes

out

when

 

pressed in

 

 

 

 

completely

control knob is released

2.

Control

knob not

pressed

2.

After ODS/Pilot lights

 

 

 

 

in long enough

 

 

 

keep control knob

 

 

 

 

 

 

 

 

 

 

 

pressed 30 seconds

 

 

 

3.

Safety

interlock

system

3.

Wait 1 (one) minute for

 

 

 

 

has

been

triggered

(if

 

safety interlock system

 

 

 

 

equipped)

 

 

 

 

to reset

 

 

 

4.

Manual

shutoff valve

not

4.

Fully open manual

 

 

 

 

fully open

 

 

 

 

shutoff valve

 

 

 

5.

Thermo-couple connection

5.

Hand tighten until snug,

 

 

 

 

loose at control valve

 

 

then tighten 1/4 turn

 

 

 

6.

Pilot

flame

not

touching

6.

Contact local propane

 

 

 

 

thermo-couple,

which

 

gas company. Clean

 

 

 

 

allows thermo-couple to

 

ODS/Pilot (See

 

 

 

 

cool causing pilot flame to

 

“Cleaning and

 

 

 

 

go out. This problem can

 

Maintenance”), or

 

 

 

 

be caused by one or both

 

replace ODS/Pilot

 

 

 

 

of the following:

 

 

 

assembly

A)low gas pressure

B)dirty or partially clogged ODS/Pilot

7. Control valve damaged

7. Replace valve control

 

 

4. Burner does not light after 1. Burner orifice is clogged ODS/Pilot is lit

2. Inlet gas pressure is too low

1.Clean burner (See “Cleaning and Maintenance”) or replace burner orifice

2.Contact local propane gas company

5. Delayed ignition of burner

1.

Manifold pressure is too

 

 

low

 

2.

Burner orifice is clogged

1.Contact local propane gas company

2.Clean burner (“See Cleaning and Mainten- ance”) or replace burner orifice

Page 29

Page 31
Image 31
New Buck Corporation FP-BR-10-ZC manual Depleted gas supply