New Buck Corporation FP-BR-10-ZC manual Burner backfiring during

Models: FP-BR-10-ZC

1 38
Download 38 pages 40.08 Kb
Page 32
Image 32

6. Burner backfiring during

1.

Burner orifice is clogged

1.

Clean burner (See “Clean-

combustion

 

or damaged

 

ing and Maintenance “) or

 

2.

Burner damaged

 

replace burner orifice

 

2.

Replace Burner

 

3.

Gas regulator defective

3.

Replace gas regulator

 

 

 

 

 

7. Slight smoke or odor

1.

Residues from

1.

Problem will stop after a

during initial operation

 

manufacturing process

 

few hours of operation

 

 

 

 

 

8. Heater produces a whist-

1.

Turning control knob to

1.

Turn control knob to

ling noise when burner is

 

“HI” position when

 

“LOW” position and allow

lit

 

burner is cold (if

 

to warm

 

 

equipped with this type

 

 

 

 

of valve)

 

 

 

2.

Air in gas line

2.

Operate burner until air is

 

 

 

 

removed from line. Call

 

 

 

 

local propane company to

 

3.

Air passageways on

 

check gas line.

 

3.

Observe minimum

 

 

heater blocked

 

installation clearances

 

4.

Dirty or partially

4.

Clean burner or replace

 

 

clogged burner orifice

 

orifice

Page 30

Page 32
Image 32
New Buck Corporation FP-BR-10-ZC manual Burner backfiring during