New Buck Corporation FS 21 installation instructions Residential and Mobile Home Installation

Models: FS 21

1 33
Download 33 pages 37.1 Kb
Page 12
Image 12

HOW TO LOCATE CHIMNEY EXIT AND INSTALL

Residential and Mobile Home Installation

C.Vertical Exit using (6" DVL Close Clearance pipe and any Listed 2100° UL 103 HT chimney). With optional close clearance shield and pipe shield.

NOTE: For installation of optional close clearance shields and pipe shield (See Page 22).

NOTE: For minimum clearances (See Page 11, Figure 6). For Required Out Side Air in Mobile Homes (See Page 14).

1.Suspend a plumb bob from the ceiling above the unit so that the weight is hanging in the center of the flue exit. (A small weight on a string will serve as a plumb bob). Mark the ceiling where the string is suspended to locate the center of the chimney.

2.After locating the center of the hole, install the ceiling support box, chimney or chimney connector, flashing and rain cap per the chimney manufacturer’s instructions and local building codes for installation through combustible walls or ceilings.

3.Now connect the stove and ceiling support box using DVL close clearance pipe. Connect each section per manufacturer’s instructions.Secure each section to each other using minimum (3) sheet metal screws or rivets.

DVL close clearance is to be connected with (3) sheet metal screws or rivets to connector collar on heater (See Page 11,Figure 7).

Page 10

Page 12
Image 12
New Buck Corporation FS 21 installation instructions Residential and Mobile Home Installation