Mtr Select (Meter Select)

Selects whether the Input levels or Output levels are displayed on the front panel L & R LED bargraph meters. Please note that in the initial release software the meters when set to monitor Output levels will only monitor the analog outputs.

Input

There are nine controls under the heading “Input” and each will be explained in the order in which they appear in the menu:

<-Exit

Click on this option to return to the Input/Output submenu.

Input Src (Input Source)

Allows the selection of Analog or AES/EBU (digital) as the primary input source to the

OmniaONE.

Fover Time (Failover Time)

Failover Time is a feature that when set to a value other than zero (disabled) allows the OmniaONE to automatically select another input source if the currently selected one fails. Failover Time is the amount of time that will elapse after the failure of audio before the unit makes the decision to switch to another input. For instance, if Failover Time is set for seven seconds and the primary audio source fails, seven seconds later the unit will switch to the secondary audio input. If, at any time, audio is restored on the primary input (for 1 second, continuously), the unit will switch back to the primary audio input. It will remain with the primary input unless another failure is detected.

Fover Src (Failover Source)

Failover Source selects which audio input: Analog or AES/EBU digital will serve as the secondary audio input. Note that the audio input that is selected under Input Source (above) will always be the Primary audio input. A source selected under Failover Source will always be the secondary source.

Anlg Level (Analog Level)

Adjusts the master audio input level for the analog inputs which are derived from the rear panel XLR female input connectors. (See Proper Setting of Input Levels on Page 26)

Right Trim

Allows a +/-3dB adjustment of the right analog audio channel gain to correct minor left/right balance problems in the input audio. The left channel analog input gain is not affected by this control and is set using the master Analog Level control previously described.

AES Level (AES/EBU Level)

Adjusts the master audio input level for the AES Digital input which is derived from the rear panel RJ-45 StudioHUBconnector. (See Proper Setting of Input Levels on Page 26)

Right Trim

OmniaONE Multicast - Use and Operation Manual – Version 0.90

41

Page 41
Image 41
New Media Technology Omnia ONE Multicast manual Mtr Select Meter Select, Input