10.5.In-service Maintenance.

10.5.1. During in-service maintenance, the range finger is checked for serviceable condition in accordance with Steps 1 through 10 of Table 9.1.

10.5.2.The unit is not to be dismantled during in-service maintenance.

10.5.3.For the servicing scope, refer to Table 10.3. Table 10.3.

The length of each leg is adjusted by retracting or extending the moving section. The coupling nut 4 must be loosened first to change the leg length.

Stay block in the bottom of the head is designated to secure the AI on a log, a stump, or any similar piece of wood suitable for the job.

6. SAFETY PRECAUTIONS

Operations

Servicing within daily scope

Cleaning contacts of charging device, protection device, wires and battery section

Repair of packing case (when so required)

Procedure as per

As in Table 10.2.

Para 10.6.1.

Materials, tools and accessories

As in Table 10.2.

Absorbent optical cotton, alcohol

Equipment, appliances and tools available in repair shop

6.1. Rangefinder LRB 20000 is an optical-electronic device emitting high-density pulses of invisible light at wavelength of

1.06µm, characterized by the following dangerous factors: - direct laser radiation;

- mirror-reflected laser radiation; - diffuse-reflected laser radiation.

Direct and mirror-reflected laser radiation of the rangefinder is dangerous for naked eyes at 1700 m distance and less.

Diffuse-reflected laser radiation is dangerous at 0.43 m distance from reflecting surface.

Optical devices increase these distances in accordance with optical device magnification ratio.

Laser energy at the output objective lens of the rangefinder exceeds permissible level for skin by 16% and reaches permissible level at 3.77 m distance from the rangefinder.

10.5.4.During in-service maintenance, the cycle life of the range finder may not be spent by more than10 measurements.

Page 17
Image 17
Newcon Optik LRB 20000 operation manual Safety Precautions, Operations, Procedure as per, Materials, tools and accessories