11.3.To correct problems by using the individual SPTA set proceed as follows (see Fig. 6).

11.3.1.To replace the fuse link 2 in the protection device: - Unscrew the threaded cover from the housing of the

protection device;

- Remove the defective fuse link;

- Insert the spare fuse link from the SPTA set;

- Screw the cover on the housing of the protection device.

11.3.2.To replace the rechargeable battery 1: - Open the cover of the battery section;

- Remove the used battery;

- Fit the new battery in the section so that the "+" terminal of the battery is connected with the bottom contact of the section;

- Close the cover of the battery section.

11.3.3.To replace the fuse link in the charging device: - Unscrew the outer threaded covers from the fuses; - Unscrew the bayonet of the fuse link holders;

- Remove the fuse links; - Fit in good fuse links; - Close the holder covers;

- Screw on the outer threaded covers.

11.3.4.The individual SPTA set includes the following tools and accessories: