7. TROUBLESHOOTING

The stabilizing mode does not work.

Check that the batteries are installed properly. Check the charge of the batteries. Replace if they are weak. Do not use old batteries with new ones.

The image does not appear in focus.

Bring the inspected object to the center of the image. Turning the eyepieces (8), adjust to achieve the clearest image on the screen. If the view still does not seem in focus, clean the lenses. They could be foggy or dusty.

Image is ‘waving’ when stabilizing mode has been engaged. This is a typical ‘warming-up’ effect that will last for no more than one minute after engaging the stabilizing mode.

Condensation accumulates on the parts

In order to avoid misting of the eyepiece lens in cold time use special protective covers.

Image has disappeared during night-time observation (using optional night eyepieces).

When bright light gets into the objective lens of the night vision device it may result in disappearing of the image as the automatic shut-off feature comes into action to protect the device. Whenever this happens, turn the switch to the OFF position. In a minute or two the device will be ready for further operation.

12

2. APPEARANCE OF THE DEVICE

1–hand strap; 2–power supply unit; 3–power supply control indicator; 4–power supply voltage switch; 5–stabilizing mode switching lever; 6–device front panel; 7–neck strap; 8–eyepieces; 9–interpupillary adjustment lever.

Fig. 1

For ease of operation, the device is fitted with neck strap (7) and hand strap (1). Eyepieces (8), interpupillary adjustment lever (9) and stabilizing mode switching lever (5) are positioned on the front panel (6) of the device. Power supply unit (2) is a detachable part of the device.

Power supply voltage switch (4) and power supply control indicator (3) are located at the front of the device.

5

Page 5
Image 5
Newcon Optik SIB 16x40 GR operation manual Troubleshooting, Appearance of the Device