ITEM# MM1007

TROUBLESHOOTING

Symptom

Cause

Power does not

 

turn on.(No

Fuse is blown

sound is

 

produced.)

 

No sound output

Power antennal lead

when operating

is shorted to ground or

the unit with

excessive current is

amplifiers or

required for remote on

power antenna

the amplifiers or

attached.

power antenna.

Nothing happens

The microprocessor

when buttons are

has malfunctioned

pressed.

due to noise, etc.

Display is not

 

Accurate

Panel or main unit

 

Connectors

 

are dirty

Sound is bad

Compact disc is dirty

directly after

 

power is turned

Compact disc is

on.

heavily scratched or

 

warped

Sound is bad

Water droplets may

directly after

form on the internal

power is turned

lens when the car is

on.

parked in a humid

 

place

Remedy

Replace with fuse of the same amperage. If the fuse blows again, consult an authorized reseller or dealer.

1.Turn off the unit.

2.Remove all wires attached to the power antenna lead. Check each

wire for a possible short to ground using an ohm meter.

1.Turn on the unit.

2.Reconnect each amplifier remote wire to the power antenna lead one by one. If the amplifiers turn off before all wires are attached, use an external replay to provide remote-on voltage(excessive current required).

Turn off the power, Then press the open button and remove the DCP. Press the reset button for about 2 seconds.

Wipe the dirt off with a soft cloth moistened with cleaning alcohol.

Carefully clean the CD with a soft cloth

Try another CD without scratches

Let it dry for about 1 hour with the power on.

34

Page 35
Image 35